Literature DB >> 23455772

Corrected right ventricular end-diastolic volume and initial distribution volume of glucose correlate with cardiac output after cardiac surgery.

Junichi Saito1, Hironori Ishihara, Eiji Hashiba, Hirobumi Okawa, Tomoyuki Kudo, Masahiro Sawada, Toshihito Tsubo, Kazuyoshi Hirota.   

Abstract

PURPOSE: Appropriate adjustment of cardiac preload is essential to maintain cardiac output (CO), especially in patients after cardiac surgery. This study was intended to determine whether index of right ventricular end-diastolic volume (RVEDVI), corrected RVEDVI using ejection fraction (cRVEDVI), index of initial distribution volume of glucose (IDVGI), or cardiac filling pressures are correlated with cardiac index (CI) following cardiac surgery in the presence or absence of arrhythmias.
METHODS: Eighty-six consecutive cardiac surgical patients were studied. Patients were divided into two groups: the non-arrhythmia (NA) group (n = 72) and the arrhythmia (A) group (n = 14). Three sets of measurements were performed: on admission to the ICU and daily on the first 2 postoperative days. The relationship between each cardiac preload variable and cardiac index (CI) was evaluated. A p value less than 0.05 indicated statistically significant differences.
RESULTS: Each studied variable was not different between the two groups immediately after admission to the ICU. cRVEDVI had a linear correlation with CI in both group (NA group: r = 0.67, n = 216, p < 0.001; A group: r = 0.77, n = 42, p < 0.001), but RVEDVI had a poor correlation with CI (NA group: r = 0.27, n = 216, p < 0.001; A group: r = 0.19, n = 42, p = 0.036). IDVGI had a linear correlation with CI (NA group: r = 0.49, n = 216, p < 0.001; A group: r = 0.61, n = 42, p < 0.001), Cardiac filling pressures had no correlation with CI.
CONCLUSION: Our results demonstrated that cRVEDVI and IDVGI were correlated with CI in the presence or absence of arrhythmias. cRVEDVI and IDVGI have potential as indirect cardiac preload markers following cardiac surgery.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23455772     DOI: 10.1007/s00540-013-1558-z

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  34 in total

Review 1.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

2.  Initial distribution volume of glucose early after cardiac surgery.

Authors:  Hironori Ishihara
Journal:  Anesth Analg       Date:  2006-06       Impact factor: 5.108

3.  Can initial distribution volume of glucose predict hypovolemic hypotension after radical surgery for esophageal cancer?

Authors:  A Suzuki; H Ishihara; H Okawa; T Tsubo; A Matsuki
Journal:  Anesth Analg       Date:  2001-05       Impact factor: 5.108

4.  Recovery of systolic and diastolic left ventricular function early after cardiopulmonary bypass.

Authors:  S G De Hert; I E Rodrigus; L R Haenen; P A De Mulder; T C Gillebert
Journal:  Anesthesiology       Date:  1996-11       Impact factor: 7.892

5.  The initial distribution volume of glucose and cardiac output in the critically ill.

Authors:  H Ishihara; Y Shimodate; H Koh; K Isozaki; T Tsubo; A Matsuki
Journal:  Can J Anaesth       Date:  1993-01       Impact factor: 5.063

6.  Preload response in patients after cardiac surgery: a comparison of systolic blood pressure and systolic area variability and initial volume of distribution of glucose.

Authors:  M Harvey; L Voss; J Sleigh
Journal:  Crit Care Resusc       Date:  2003-09       Impact factor: 2.159

7.  Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans.

Authors:  K Hirota; H Ishihara; T Tsubo; A Matsuki
Journal:  Br J Clin Pharmacol       Date:  1999-04       Impact factor: 4.335

8.  Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.

Authors:  Anand Kumar; Ramon Anel; Eugene Bunnell; Kalim Habet; Sergio Zanotti; Stephanie Marshall; Alex Neumann; Amjad Ali; Mary Cheang; Clifford Kavinsky; Joseph E Parrillo
Journal:  Crit Care Med       Date:  2004-03       Impact factor: 7.598

9.  Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.

Authors:  Rose-Marieke B G E Breukers; Shahrzad Sepehrkhouy; Stefan R Spiegelenberg; A B Johan Groeneveld
Journal:  J Cardiothorac Vasc Anesth       Date:  2007-04-05       Impact factor: 2.628

10.  Use of initial distribution volume of glucose to determine fluid volume loading in pulmonary thromboembolism and right ventricular myocardial infarction.

Authors:  Eiji Hashiba; Hironori Ishihara; Toshihito Tsubo; Hirobumi Okawa; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

View more
  2 in total

1.  Effects of cardiac output on the initial distribution volume of glucose in the absence of fluid gain or loss in pigs.

Authors:  Toshinori Kasai; Eiji Hashiba; Junichi Saito; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2016-10-26       Impact factor: 2.078

2.  Basic and clinical assessment of initial distribution volume of glucose in hemodynamically stable pediatric intensive care patients.

Authors:  Hironori Ishihara; Eiji Hashiba; Hirobumi Okawa; Junichi Saito; Toshinori Kasai; Toshihito Tsubo
Journal:  J Intensive Care       Date:  2014-11-12
  2 in total