Literature DB >> 9660549

Arterial phase carotid and vertebral artery imaging in 3D contrast-enhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order.

A H Wilman1, S J Riederer, J Huston, J T Wald, J P Debbins.   

Abstract

Arterial-phase three-dimensional (3D) contrast-enhanced MR angiograms of the carotid and vertebral arteries from their origins through the carotid bifurcations were obtained in 20 patients using acquisition times over 30 sec by using an MR fluoroscopy-triggered pulse sequence with elliptical centric view order. The typical pixel size was 0.8 mm (x) x 1.6 mm (y) x 1.5 mm (z), and 32-48 coronal slices were acquired. The fluoroscopic monitoring of bolus arrival was effective in 18 of the 20 cases; two failures were attributed directly to a poor choice of RF coil. To exploit peak arterial-to-venous contrast, the central 3D views were acquired first in the most compact time period possible for the given TR. For the 18 successfully triggered cases, arterial-phase 3D images were obtained with excellent venous suppression as demonstrated by an average internal jugular vein to common carotid signal enhancement ratio of only 0.05 +/- 0.04.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9660549     DOI: 10.1002/mrm.1910400104

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  Int J Card Imaging       Date:  1999-04

2.  Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

3.  Dynamic contrast-enhanced MR angiography and MR imaging of the carotid artery: high-resolution sequences in different acquisition planes.

Authors:  S Aoki; H Nakajima; H Kumagai; T Araki
Journal:  AJNR Am J Neuroradiol       Date:  2000-02       Impact factor: 3.825

Review 4.  Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time-resolved technique.

Authors:  Taylor Chung
Journal:  Pediatr Radiol       Date:  2004-06-22

5.  Improved venous suppression and spatial resolution with SENSE in elliptical centric 3D contrast-enhanced MR angiography.

Authors:  Houchun H Hu; Ananth J Madhuranthakam; David G Kruger; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

6.  High-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with fourfold accelerated two-dimensional sensitivity encoding.

Authors:  Houchun H Hu; Norbert G Campeau; John Huston; David G Kruger; Clifton R Haider; Stephen J Riederer
Journal:  Radiology       Date:  2007-04-19       Impact factor: 11.105

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.