Literature DB >> 9655710

Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.

B Valtier1, B P Cholley, J P Belot, J E de la Coussaye, J Mateo, D M Payen.   

Abstract

Measurement of cardiac output using thermodilution technique in mechanically ventilated patients is associated with significant morbidity. The goal of the present study was to assess the validity of cardiac output measurement using transesophageal Doppler in critically ill patients. Forty-six patients from three different intensive care units underwent 136 paired cardiac output measurements using thermodilution (COTH) and transesophageal Doppler (COTED). In addition, simultaneous suprasternal Doppler and indirect calorimetry (Fick principle) were used to measure cardiac output in 26 patients from one center. A good correlation was found between COTH and COTED (r = 0.95), with a small systematic underestimation (bias = 0.24 L/min) using transesophageal Doppler. The limits of agreement between COTH and COTED were +2 L/min and -1.5 L/min. Variations in cardiac output between two consecutive measures using either transesophageal Doppler or thermodilution techniques were similar in direction and magnitude (bias = 0 L/min; limits of agreement = +/-1.7 L/min). Suprasternal Doppler and indirect calorimetry yielded similar correlations and agreements in the subset of patients in whom they were used. These results confirm that transesophageal Doppler can provide a noninvasive, clinically useful estimate of cardiac output and detect hemodynamic changes in mechanically ventilated, critically ill patients.

Entities:  

Mesh:

Year:  1998        PMID: 9655710     DOI: 10.1164/ajrccm.158.1.9707031

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  31 in total

1.  Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.

Authors:  M Rupérez; J López-Herce; C García; C Sánchez; E García; D Vigil
Journal:  Pediatr Cardiol       Date:  2003-12-23       Impact factor: 1.655

2.  Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler.

Authors:  Michel Slama; Henri Masson; Jean-Louis Teboul; Marie-Luce Arnould; Rachida Nait-Kaoudjt; Bouchra Colas; Marcel Peltier; Christophe Tribouilloy; Dinko Susic; Edward Frohlich; Michel Andréjak
Journal:  Intensive Care Med       Date:  2004-03-05       Impact factor: 17.440

3.  Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?

Authors:  Huang Li; Lester A H Critchley; Jie Zhang
Journal:  J Clin Monit Comput       Date:  2015-08-28       Impact factor: 2.502

4.  A novel approach to measure cardiac output noninvasively: a comparison with the thermodilution method on critical care patients.

Authors:  John Kabal; Bruce K Lagerman
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

Review 5.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

6.  Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume.

Authors:  Scott R Gunn; Hyung Kook Kim; Peter W J Harrigan; Michael R Pinsky
Journal:  Intensive Care Med       Date:  2006-07-28       Impact factor: 17.440

7.  A new modality for the estimation of corrected flow time via electrocardiography as an alternative to Doppler ultrasonography.

Authors:  Hooman Hossein-Nejad; Payam Mohammadinejad; Atefeh Zeinoddini; Seyedhossein Seyedhosseini Davarani; Mohsen Banaie
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-04-22       Impact factor: 1.468

8.  Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery.

Authors:  Moira McKendry; Helen McGloin; Debbie Saberi; Libby Caudwell; Anthony R Brady; Mervyn Singer
Journal:  BMJ       Date:  2004-07-08

9.  Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients.

Authors:  Hasse Møller-Sørensen; Joakim Cordtz; Morten Østergaard; Jens C Nilsson; Kristoffer L Hansen
Journal:  J Clin Monit Comput       Date:  2015-11-17       Impact factor: 2.502

10.  Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans.

Authors:  José Marquez; Kenneth McCurry; Donald A Severyn; Michael R Pinsky
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

View more