Ability of pulse contour and esophageal Doppler to estimate rapid changes in stroke volume.

Scott R Gunn1, Hyung Kook Kim, Peter W J Harrigan, Michael R Pinsky.   

Abstract

OBJECTIVE: Two technologies to acquire beat-to-beat stroke volume values exist, pulse contour analysis and esophageal Doppler monitoring. Pulse contour analysis assumes fixed aortic impedance. Esophageal Doppler assumes a constant proportional descending aortic flow and diameter. These assumptions may not be correct as arterial tone or myocardial contractility vary. We tested these relationships in the setting of rapidly changing stroke volumes and different cardiovascular states over a period of 10-15 cardiac cycles. DESIGN AND
SETTING: In a university research facility we compared beat-to-beat changes in stroke volume as measure by aortic root flow probe or conductance catheter to pulse contour analysis and stroke distance as measured by esophageal Doppler.
SUBJECTS: Five purpose-bred research hounds.
INTERVENTIONS: To obtain a wide range of rapidly changing stroke volumes measurements were made during transient inferior vena cava occlusion. Data were gathered under baseline conditions and during norepinephrine, nitroprusside, and dobutamine infusions. MEASUREMENTS AND
RESULTS: The pulse contour stroke volumes and esophageal Doppler stroke distance paralleled flow probe stroke volumes under all conditions (R(2)=0.89 for all measures). However, the absolute changes and proportional changes and the absolute values for both surrogate measures differed from absolute stroke volumes. Bland-Altman analysis showed no consistent bias or degree of precision across all animals under any given cardiovascular state.
CONCLUSIONS: Both pulse contour stroke volumes and esophageal Doppler derived stroke distance estimates yield significant correlations with aortic root flow probe. However, the absolute values, absolute changes, or proportional changes may not reflect actual stroke volumes as cardiovascular state varies, making their use in estimating absolute changes in stroke volume potentially inaccurate.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16874496     DOI: 10.1007/s00134-006-0284-5

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  15 in total

1.  Less invasive, continuous hemodynamic monitoring during minimally invasive coronary surgery.

Authors:  O Gödje; C Thiel; P Lamm; H Reichenspurner; C Schmitz; A Schütz; B Reichart
Journal:  Ann Thorac Surg       Date:  1999-10       Impact factor: 4.330

2.  Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability.

Authors:  Oliver Gödje; Kerstin Höke; Alwin E Goetz; Thomas W Felbinger; Daniel A Reuter; Bruno Reichart; Reinhard Friedl; Andreas Hannekum; Ulrich J Pfeiffer
Journal:  Crit Care Med       Date:  2002-01       Impact factor: 7.598

3.  Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique.

Authors:  G Della Rocca; M G Costa; L Pompei; C Coccia; P Pietropaoli
Journal:  Br J Anaesth       Date:  2002-03       Impact factor: 9.166

4.  Continuous hemodynamic monitoring by esophageal Doppler.

Authors:  M Singer; J Clarke; E D Bennett
Journal:  Crit Care Med       Date:  1989-05       Impact factor: 7.598

5.  Noninvasive optimization of left ventricular filling using esophageal Doppler.

Authors:  M Singer; E D Bennett
Journal:  Crit Care Med       Date:  1991-09       Impact factor: 7.598

6.  Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock.

Authors:  M Feissel; F Michard; I Mangin; O Ruyer; J P Faller; J L Teboul
Journal:  Chest       Date:  2001-03       Impact factor: 9.410

7.  Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients.

Authors:  Xavier Monnet; Mario Rienzo; David Osman; Nadia Anguel; Christian Richard; Michael R Pinsky; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2005-07-30       Impact factor: 17.440

8.  Effects of fentanyl and diazepam in dogs deprived of autonomic tone.

Authors:  J W Flacke; L J Davis; W E Flacke; B C Bloor; A P Van Etten
Journal:  Anesth Analg       Date:  1985-11       Impact factor: 5.108

9.  Effects of fentanyl on coronary blood flow distribution and myocardial oxygen consumption in the dog.

Authors:  L J Hirsch; M W Rooney; M Mathru; T L Rao
Journal:  J Cardiothorac Vasc Anesth       Date:  1993-02       Impact factor: 2.628

10.  Fentanyl's analgesic, respiratory, and cardiovascular actions in relation to dose and plasma concentration in unanesthetized dogs.

Authors:  J O Arndt; M Mikat; C Parasher
Journal:  Anesthesiology       Date:  1984-10       Impact factor: 7.892

View more
  9 in total

1.  Both passive leg raising and intravascular volume expansion improve sublingual microcirculatory perfusion in severe sepsis and septic shock patients.

Authors:  Julien Pottecher; Stéphane Deruddre; Jean-Louis Teboul; Jean-François Georger; Christian Laplace; Dan Benhamou; Eric Vicaut; Jacques Duranteau
Journal:  Intensive Care Med       Date:  2010-08-20       Impact factor: 17.440

2.  Standard pulse contour methods are not applicable in animals.

Authors:  Jos R Jansen
Journal:  Intensive Care Med       Date:  2006-10-20       Impact factor: 17.440

3.  Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans.

Authors:  José Marquez; Kenneth McCurry; Donald A Severyn; Michael R Pinsky
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

4.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

5.  Effect of different analgesic techniques on hemodynamic variables recorded with an esophageal Doppler monitor during ovariohysterectomy in dogs.

Authors:  Ignacio Sández; María Soto; Daniel Torralbo; Eva Rioja
Journal:  Can Vet J       Date:  2018-04       Impact factor: 1.008

6.  Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Manuel Gracia Romero
Journal:  Crit Care       Date:  2011-01-12       Impact factor: 9.097

7.  Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study.

Authors:  Manuel Ignacio Monge García; Manuel Gracia Romero; Anselmo Gil Cano; Hollmann D Aya; Andrew Rhodes; Robert Michael Grounds; Maurizio Cecconi
Journal:  Crit Care       Date:  2014-11-19       Impact factor: 9.097

8.  Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs.

Authors:  Seijirow Goya; Tomoki Wada; Kazumi Shimada; Daiki Hirao; Ryuji Fukushima; Norio Yamagishi; Miki Shimizu; Ryou Tanaka
Journal:  J Vet Med Sci       Date:  2016-12-16       Impact factor: 1.267

Review 9.  Year in review in Intensive Care Medicine, 2006. II. Infections and sepsis, haemodynamics, elderly, invasive and noninvasive mechanical ventilation, weaning, ARDS.

Authors:  Peter Andrews; Elie Azoulay; Massimo Antonelli; Laurent Brochard; Christian Brun-Buisson; Daniel De Backer; Geoffrey Dobb; Jean-Yves Fagon; Herwig Gerlach; Johan Groeneveld; Duncan Macrae; Jordi Mancebo; Philipp Metnitz; Stefano Nava; Jerôme Pugin; Michael Pinsky; Peter Radermacher; Christian Richard
Journal:  Intensive Care Med       Date:  2007-01-13       Impact factor: 17.440

  9 in total