Literature DB >> 9641421

Posterior chamber phakic intraocular lens for hyperopia of +4 to +11 diopters.

J M Davidorf1, R Zaldivar, S Oscherow.   

Abstract

PURPOSE: To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in eyes with high hyperopia.
METHODS: We analyzed the results of 24 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of hyperopia with the goal of emmetropia. Mean follow-up was 8.4 months (range, 1 to 18 mo).
RESULTS: The mean preoperative spherical equivalent refraction was +6.51 +/- 2.08 D (range, +3.75 to +10.50 D). Mean postoperative spherical equivalent refraction at last examination was -0.39 +/- 1.29 D (range, +1.25 to -3.88 D), with 79% (19 eyes) within +/-1.00 D and 58% (14 eyes) within +/-0.50 D of emmetropia. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 8% (two eyes) and 20/40 or better in 63% (15 eyes). A gain of two or more lines of spectacle-corrected visual acuity was seen in two eyes (8%) at last examination. One eye (4%) lost two or more lines of spectacle-corrected visual acuity due to progressive neovascular glaucoma initiated by early postoperative pupillary block.
CONCLUSION: Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective method for correcting high hyperopia. Large, patent iridotomies are important in hyperopic eyes to lower the risk of postoperative pupillary block. Improved phakic IOL power calculation formulas will refine predictability of refractive outcome.

Entities:  

Mesh:

Year:  1998        PMID: 9641421     DOI: 10.3928/1081-597X-19980501-14

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  18 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

Review 4.  [Scheimpflug photography for the examination of phakic intraocular lenses].

Authors:  M Baumeister
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

5.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

6.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

Review 7.  Complications of cataract and refractive surgery: a clinicopathological documentation.

Authors:  D J Apple; L Werner
Journal:  Trans Am Ophthalmol Soc       Date:  2001

8.  Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant.

Authors:  M Vetrugno; N Cardascia; L Cardia
Journal:  Br J Ophthalmol       Date:  2000-10       Impact factor: 4.638

9.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003

10.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.