Literature DB >> 9609887

Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model.

K T Bae1, J P Heiken, J A Brink.   

Abstract

PURPOSE: To investigate how reduction in cardiac output affects the magnitude and timing of aortic and hepatic contrast medium enhancement during abdominal computed tomography (CT).
MATERIALS AND METHODS: Eight 20-30-kg pigs underwent CT before and after pharmacologic reduction of cardiac output (measured by means of thermodilution). Each CT study consisted of 53 dynamic images acquired every 5 seconds at a fixed level through the midliver after intravenous injection of contrast medium (concentration, 282 mg of iodine per milliliter; dose, 2 mL per kilogram of body weight; injection rate, 2 mL/sec). Curves of contrast medium enhancement versus time were measured. Changes in the magnitude and timing of aortic and hepatic enhancement were compared with the reduction in cardiac output.
RESULTS: With reduction in cardiac output, the time from the injection start to the arrival of the contrast medium bolus in the aorta (P < .01) and the times from injection completion to peak aortic (P < .01) and peak hepatic (P < .01) enhancement increased. As cardiac output decreased, peak aortic enhancement increased proportionally (P < .01). Peak hepatic enhancement increased only slightly and correlated weakly with the decrease in cardiac output (P = .07).
CONCLUSION: As cardiac output decreases, the times to the arrival of the contrast medium bolus in the aorta and to peak aortic and hepatic enhancement increase. Reduction in cardiac output results in a substantial increase in peak aortic enhancement but not in peak hepatic enhancement.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9609887     DOI: 10.1148/radiology.207.3.9609887

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  63 in total

Review 1.  Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Standardisation of liver MDCT by tracking liver parenchyma enhancement to trigger imaging.

Authors:  H Brodoefel; A Tognolini; G A Zamboni; S Gourtsoyianni; C D Claussen; V Raptopoulos
Journal:  Eur Radiol       Date:  2011-11-05       Impact factor: 5.315

3.  Hepatic computed tomography perfusion: comparison of maximum slope and dual-input single-compartment methods.

Authors:  Tomonori Kanda; Takeshi Yoshikawa; Yoshiharu Ohno; Naoki Kanata; Hisanobu Koyama; Munenobu Nogami; Daisuke Takenaka; Kazuro Sugimura
Journal:  Jpn J Radiol       Date:  2010-12-30       Impact factor: 2.374

4.  Individually tailored contrast enhancement in CT pulmonary angiography.

Authors:  Babs M F Hendriks; Madeleine Kok; Casper Mihl; Sebastiaan C A M Bekkers; Joachim E Wildberger; Marco Das
Journal:  Br J Radiol       Date:  2016-01-22       Impact factor: 3.039

5.  Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

Authors:  Hee Jeong Shin; Song Soo Kim; Jae-Hwan Lee; Jae-Hyeong Park; Jin-Ok Jeong; Seon Ah Jin; Byung Seok Shin; Kyung-Sook Shin; Moonsang Ahn
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

6.  Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: phantom and patient studies.

Authors:  Kazuo Awai; Yoshiharu Nakayama; Takeshi Nakaura; Yumi Yanaga; Yoshitaka Tamura; Masahiro Hatemura; Yoshinori Funama; Yasuyuki Yamashita
Journal:  Radiat Med       Date:  2007-01-25

7.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

8.  Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Fabian M Tay; Nina Burkhard; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-19       Impact factor: 2.357

9.  Operation of bolus tracking system for prediction of aortic peak enhancement at multidetector row computed tomography: pharmacokinetic analysis and clinical study.

Authors:  Isao Yamaguchi; Hiroyuki Hayashi; Masayuki Suzuki; Katsuhiro Ichikawa; Eiji Kidoya; Hirohiko Kimura
Journal:  Radiat Med       Date:  2008-07-27

10.  MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates.

Authors:  S Keil; C Plumhans; F F Behrendt; M Das; S Stanzel; G Mühlenbruch; P Seidensticker; C Knackstedt; A H Mahnken; R W Günther; J E Wildberger
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.