Literature DB >> 9608434

Biochemical classification of kidney carcinoma biopsy samples using magic-angle-spinning 1H nuclear magnetic resonance spectroscopy.

D Moka1, R Vorreuther, H Schicha, M Spraul, E Humpfer, M Lipinski, P J Foxall, J K Nicholson, J C Lindon.   

Abstract

High resolution 1H nuclear magnetic resonance (NMR) spectra using spinning at the magic angle (1H MAS NMR) have been obtained on intact normal and pathological kidney tissue samples from patients undergoing surgery for renal cell carcinoma (RCC). The spectra were measured on ca. 80 mg samples and provided high resolution 1H NMR spectra in which effects of dipolar couplings, chemical shift anisotropy and magnetic susceptibility differences are minimised thus yielding high spectral resolution. Conventional one-dimensional and spin-echo spectra and two-dimensional J-resolved, TOCSY and 1H-13C HMQC spectra were also measured on selected samples and these allowed the assignment of resonances of endogenous substances comprising both cytosolic and membrane components. The tumour tissues were characterised principally by an increased lipid content. These are the first reported results on human tumour tissues using this technique and the approach offers potential for the rapid classification of different types of tumour tissue.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9608434     DOI: 10.1016/s0731-7085(97)00176-3

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  19 in total

1.  High-resolution magic-angle-spinning NMR spectroscopy for metabolic profiling of intact tissues.

Authors:  Olaf Beckonert; Muireann Coen; Hector C Keun; Yulan Wang; Timothy M D Ebbels; Elaine Holmes; John C Lindon; Jeremy K Nicholson
Journal:  Nat Protoc       Date:  2010-05-13       Impact factor: 13.491

Review 2.  The application of NMR-based metabonomics in neurological disorders.

Authors:  Elaine Holmes; Tsz M Tsang; Sarah J Tabrizi
Journal:  NeuroRx       Date:  2006-07

3.  The effect of single and repeated UVB radiation on rabbit cornea.

Authors:  Miroslav Fris; May-Britt Tessem; Jitka Cejková; Anna Midelfart
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-12       Impact factor: 3.117

Review 4.  Metabonomics techniques and applications to pharmaceutical research & development.

Authors:  John C Lindon; Elaine Holmes; Jeremy K Nicholson
Journal:  Pharm Res       Date:  2006-05-25       Impact factor: 4.200

Review 5.  Applications of metabolomics to study cancer metabolism.

Authors:  Akash K Kaushik; Ralph J DeBerardinis
Journal:  Biochim Biophys Acta Rev Cancer       Date:  2018-04-25       Impact factor: 10.680

6.  Comparison of in vivo 1H MRS of human brain tumours with 1H HR-MAS spectroscopy of intact biopsy samples in vitro.

Authors:  S J Barton; F A Howe; A M Tomlins; S A Cudlip; J K Nicholson; B A Bell; J R Griffiths
Journal:  MAGMA       Date:  1999-05       Impact factor: 2.310

7.  NMR-spectroscopy for nontargeted screening and simultaneous quantification of health-relevant compounds in foods: the example of melamine.

Authors:  Dirk W Lachenmeier; Eberhard Humpfer; Fang Fang; Birk Schütz; Peter Dvortsak; Constanze Sproll; Manfred Spraul
Journal:  J Agric Food Chem       Date:  2009-08-26       Impact factor: 5.279

Review 8.  Applications of high-resolution magic angle spinning MRS in biomedical studies II-Human diseases.

Authors:  Christopher Dietz; Felix Ehret; Francesco Palmas; Lindsey A Vandergrift; Yanni Jiang; Vanessa Schmitt; Vera Dufner; Piet Habbel; Johannes Nowak; Leo L Cheng
Journal:  NMR Biomed       Date:  2017-09-15       Impact factor: 4.044

Review 9.  Metabolomics-based methods for early disease diagnostics.

Authors:  G A Nagana Gowda; Shucha Zhang; Haiwei Gu; Vincent Asiago; Narasimhamurthy Shanaiah; Daniel Raftery
Journal:  Expert Rev Mol Diagn       Date:  2008-09       Impact factor: 5.225

10.  Quantification of choline- and ethanolamine-containing metabolites in human prostate tissues using 1H HR-MAS total correlation spectroscopy.

Authors:  Mark G Swanson; Kayvan R Keshari; Z Laura Tabatabai; Jeffry P Simko; Katsuto Shinohara; Peter R Carroll; Andrew S Zektzer; John Kurhanewicz
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.