Literature DB >> 9597767

A quadrupole ion trap/time-of-flight mass spectrometer with a parabolic reflectron.

V M Doroshenko1, R J Cotter.   

Abstract

A matrix-assisted laser desorption/ionization-quadrupole ion trap/reflectron time-of-flight (MALDI-QIT/reTOF) mass spectrometer design and its operation in both normal and tandem mass spectrometric modes are described. A parabolic reflectron was found to be capable of providing mass resolution of 5000 for an initial ion energy distribution ranging over a 50% energy interval of the entire reflectron energy range. The sensitivity, ion isolation and fragmentation efficiency in the MALDI-QIT/reTOF instrument were close to those observed in the MALDI/QIT mass spectrometer. The mass resolution was shown to depend on the extraction field potentials, the r.f. trapping voltage amplitude and the phase of shutting down the r.f. voltage before extraction. At values of qs < 0.3-0.4 the mass resolution does not depend on the ion mass, is in a range of 1000-1400 and is governed by the extraction voltages and the ion temperature before extraction, the latter shown to be in the range 1180-1690 K. The variation of the mass resolution for ions at values of qs > 0.4 is irregular but normally it is lower than that for ions having lower qs values. Mass spectral line positions shifted when the trapping voltage before extraction was varied. The line shifts were larger for lower mass ions and were comparable to the line widths in the case of very low masses.

Mesh:

Substances:

Year:  1998        PMID: 9597767     DOI: 10.1002/(SICI)1096-9888(199804)33:4<305::AID-JMS635>3.0.CO;2-9

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  7 in total

1.  Tandem time-of-flight mass spectrometer for photodissociation of biopolymer ions generated by matrix-assisted laser desorption ionization (MALDI-TOF-PD-TOF) using a linear-plus-quadratic potential reflectron.

Authors:  Joo Yeon Oh; Jeong Hee Moon; Myung Soo Kim
Journal:  J Am Soc Mass Spectrom       Date:  2004-08       Impact factor: 3.109

Review 2.  Hybrid mass spectrometers for tandem mass spectrometry.

Authors:  Gary L Glish; David J Burinsky
Journal:  J Am Soc Mass Spectrom       Date:  2007-11-29       Impact factor: 3.109

3.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia Ibrahim; Mikhail E Belov; Aleksey V Tolmachev; David C Prior; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-13       Impact factor: 6.986

4.  Accelerated simulation study of space charge effects in quadrupole ion traps using GPU techniques.

Authors:  Xingchuang Xiong; Wei Xu; Xiang Fang; Yulin Deng; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2012-08-09       Impact factor: 3.109

5.  Analysis of protein glycosylation and phosphorylation using liquid phase separation, protein microarray technology, and mass spectrometry.

Authors:  Jia Zhao; Tasneem H Patwa; Manoj Pal; Weilian Qiu; David M Lubman
Journal:  Methods Mol Biol       Date:  2009

6.  On-line capillary liquid chromatography tandem mass spectrometry on an ion trap/reflectron time-of-flight mass spectrometer using the sequence tag database search approach for peptide sequencing and protein identification.

Authors:  P Huang; D B Wall; S Parus; D M Lubman
Journal:  J Am Soc Mass Spectrom       Date:  2000-02       Impact factor: 3.262

7.  Recent trends in mass spectrometer development.

Authors:  James W Hager
Journal:  Anal Bioanal Chem       Date:  2003-11-04       Impact factor: 4.142

  7 in total