Literature DB >> 10689665

On-line capillary liquid chromatography tandem mass spectrometry on an ion trap/reflectron time-of-flight mass spectrometer using the sequence tag database search approach for peptide sequencing and protein identification.

P Huang1, D B Wall, S Parus, D M Lubman.   

Abstract

Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10689665     DOI: 10.1016/S1044-0305(99)00128-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.262


  23 in total

1.  An investigation of fragmentation mechanisms of doubly protonated tryptic peptides.

Authors:  X J Tang; R K Boyd
Journal:  Rapid Commun Mass Spectrom       Date:  1992-11       Impact factor: 2.419

2.  Microfabricated device coupled with an electrospray ionization quadrupole time-of-flight mass spectrometer: protein identifications based on enhanced-resolution mass spectrometry and tandem mass spectrometry data.

Authors:  D Figeys; C Lock; L Taylor; R Aebersold
Journal:  Rapid Commun Mass Spectrom       Date:  1998       Impact factor: 2.419

3.  Optimization of capillary chromatography ion trap-mass spectrometry for identification of gel-separated proteins.

Authors:  P L Courchesne; M D Jones; J H Robinson; C S Spahr; S McCracken; D L Bentley; R Luethy; S D Patterson
Journal:  Electrophoresis       Date:  1998-05       Impact factor: 3.535

4.  High sensitivity collisionally-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer.

Authors:  H R Morris; T Paxton; A Dell; J Langhorne; M Berg; R S Bordoli; J Hoyes; R H Bateman
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

5.  Analysis of tryptic digests using microbore HPLC with an ion trap storage/reflectron time-of-flight detector.

Authors:  M G Qian; D M Lubman
Journal:  Anal Chem       Date:  1995-09-01       Impact factor: 6.986

Review 6.  Mass spectrometry and the age of the proteome.

Authors:  J R Yates
Journal:  J Mass Spectrom       Date:  1998-01       Impact factor: 1.982

7.  A quadrupole ion trap/time-of-flight mass spectrometer with a parabolic reflectron.

Authors:  V M Doroshenko; R J Cotter
Journal:  J Mass Spectrom       Date:  1998-04       Impact factor: 1.982

8.  Rapid 'de novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer.

Authors:  A Shevchenko; I Chernushevich; W Ens; K G Standing; B Thomson; M Wilm; M Mann
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

9.  Protein digest analysis by pressurized capillary electrochromatography using an ion trap storage/reflectron time-of-flight mass detector.

Authors:  J T Wu; P Huang; M X Li; D M Lubman
Journal:  Anal Chem       Date:  1997-08-01       Impact factor: 6.986

10.  Advanced stored waveform inverse Fourier transform technique for a matrix-assisted laser desorption/ionization quadrupole ion trap mass spectrometer.

Authors:  V M Doroshenko; R J Cotter
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

View more
  4 in total

1.  Microwave-assisted enzyme-catalyzed reactions in various solvent systems.

Authors:  Shan-Shan Lin; Chi-Hong Wu; Mei-Chuan Sun; Chung-Ming Sun; Yen-Peng Ho
Journal:  J Am Soc Mass Spectrom       Date:  2005-04       Impact factor: 3.109

2.  Improving mass defect filters for human proteins.

Authors:  Melinda L Toumi; Heather Desaire
Journal:  J Proteome Res       Date:  2010-10-01       Impact factor: 4.466

3.  Current awareness on comparative and functional genomics.

Authors: 
Journal:  Yeast       Date:  2000-09-30       Impact factor: 3.239

4.  Investigation of non-enzymatic glycosylation of human serum albumin using ion trap-time of flight mass spectrometry.

Authors:  Xue Bai; Zhangjie Wang; Chengcai Huang; Zhe Wang; Lianli Chi
Journal:  Molecules       Date:  2012-07-25       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.