Literature DB >> 9586476

An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design.

M R Norton1.   

Abstract

Dental implants are subject to large and highly complex loads of varying magnitude, duration and vector. Bridge performance is closely related to load transmission both at the bone to implant interface and between components within the implant-abutment-bridge cylinder complex. The design of the interface between components within this complex may have a profound influence on the long term function of the implant supported prosthesis. An in vitro evaluation of implants 3.5 mm in diameter, utilizing an internal conical interface has demonstrated increased resistance to bending moments at the fixture-abutment interface (P = 0.00010) and at the abutment-bridge cylinder interface (P < 0.01), when compared to a standard 3.75 mm implant with a hex mediated, butt joint interface. The relatively small values for coefficient of variance measured in both systems would confirm that whilst the size of data is small, it is nonetheless a reliable indication of the relative strength of these implant designs.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9586476     DOI: 10.1034/j.1600-0501.1997.080407.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  17 in total

Review 1.  Management of abutment screw loosening: review of literature and report of a case.

Authors:  Vinod Krishnan; C Tony Thomas; Ipe Sabu
Journal:  J Indian Prosthodont Soc       Date:  2013-10-25

2.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

3.  The change of rotational freedom following different insertion torques in three implant systems with implant driver.

Authors:  Joo-Hyun Kwon; Chong-Hyun Han; Sun-Jai Kim; Jae-Seung Chang
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

4.  Compressive fatigue in titanium dental implants submitted to fluoride ions action.

Authors:  Ana Lúcia Roselino Ribeiro; Jorge Roberto Noriega; Fábio Roberto Dametto; Luís Geraldo Vaz
Journal:  J Appl Oral Sci       Date:  2007-08       Impact factor: 2.698

5.  A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments.

Authors:  Ji-Man Park; Jai-Bong Lee; Seong-Joo Heo; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

6.  Stability of external and internal implant connections after a fatigue test.

Authors:  Paulo Cesar Pinheiro Feitosa; Ana Paula Barbosa de Lima; Laís Regiane Silva-Concílio; William Cunha Brandt; Ana Christina Claro Neves
Journal:  Eur J Dent       Date:  2013-07

7.  Resistance of three implant-abutment interfaces to fatigue testing.

Authors:  Cleide Gisele Ribeiro; Maria Luiza Cabral Maia; Susanne S Scherrer; Antonio Carlos Cardoso; H W Anselm Wiskott
Journal:  J Appl Oral Sci       Date:  2011-07-01       Impact factor: 2.698

8.  A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone.

Authors:  Hasan Sarfaraz; Anoopa Paulose; K Kamalakanth Shenoy; Akhter Hussain
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

9.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

10.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug
View more