Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla.

N Meredith1, K Book, B Friberg, T Jemt, L Sennerby.   

Abstract

The aim of this investigation was to evaluate the use of resonance frequency measurements in the clinical measurement of implant stability. Resonance frequency measurements are undertaken by measuring the response of a small transducer attached to an implant fixture or abutment. Two groups of patients were selected for study. Group A comprised 9 patients who had a total of 56 implants placed. Resonance frequency measurements were made at fixture installation and repeated 8 months later at abutment connection. The resonance frequency of the implant/transducer system increased for 50 out of the 56 implants from a mean value of 7473 Hz +/- 127 Hz (P < 0.05) to a mean of 7915 Hz +/- 112 Hz (P < 0.05). Two implants had failed to integrate and the resonance frequency of these had fallen. Group B comprised 9 patients who had been provided with fixed prostheses and had a total of 52 implants placed. They were examined 5 years after fixture placement and the prostheses removed. All implants were judged clinically to be osseointegrated. The level of the marginal bone around each implant was calculated by measuring the number of exposed threads on intraoral periapical radiographs and added to the length of each abutment to give a value termed the effective implant length (EIL). Measurements indicated a correlation (R = -0.78, P < 0.01) between EIL and resonance frequency. The results support the hypothesis that the resonance frequency of an implant/transducer system is related to the height of the implant not surrounded by bone and the stability of the implant/tissue interface as determined by the absence of clinical mobility.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9586467     DOI: 10.1034/j.1600-0501.1997.080309.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  49 in total

1.  [Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig].

Authors:  A Büchter; J Kleinheinz; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2003-10-24

2.  Natural frequency assessment of stability of root keeper magnetic devices.

Authors:  H M Huang; D Z Liu; Y Y Shiau; C Y Yeh; C T Lin; S Y Lee
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

3.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

Review 4.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

5.  Predictive values of resonance frequency analysis as a diagnostic tool in palatal implant loss.

Authors:  Katja Wieczorek; Winfried Harzer; Heinrich Wehrbein; Maximilian Moergel; Martin Kunkel; Britta A Jung
Journal:  Angle Orthod       Date:  2019-03-18       Impact factor: 2.079

6.  Sinus implants stabilization in Misch IV Class by means of S.I.S. device: A Clinical Study.

Authors:  C Grandi; L Pacifici
Journal:  Oral Implantol (Rome)       Date:  2010-05-25

7.  Ability of modal analysis to detect osseointegration of implants in transfemoral amputees: a physical model study.

Authors:  Nicola J Cairns; Mark J Pearcy; James Smeathers; Clayton J Adam
Journal:  Med Biol Eng Comput       Date:  2012-10-06       Impact factor: 2.602

8.  Highly Nonlinear Solitary Waves for the Assessment of Dental Implant Mobility.

Authors:  Bruk Berhanu; Piervincenzo Rizzo; Mark Ochs
Journal:  J Appl Mech       Date:  2012-11-20       Impact factor: 2.168

9.  A comparison of the implant stability among various implant systems: clinical study.

Authors:  Jae-Min Kim; Sun-Jong Kim; Inho Han; Sang-Wan Shin; Jae-Jun Ryu
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

10.  A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient.

Authors:  Dae-Hyun Lee; Young Ku; In-Chul Rhyu; Jeong-Ug Hong; Cheol-Woo Lee; Min-Suk Heo; Kyung-Hoe Huh
Journal:  J Periodontal Implant Sci       Date:  2010-02-28       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.