Literature DB >> 9577103

In vitro testing of a measuring system for in vivo recording of orthodontically applied forces and moments in the multiband technique. Part II.

D Friedrich1, N Rosarius, P Schwindke, G Rau, P Diedrich.   

Abstract

The aim of this study was to measure in vivo the forces and moments acting therapeutically on the individual tooth in connection with the multiband technique. Securing and evaluating the planned in vivo measurements involves analysing the measuring accuracy of the system as a whole by means of corresponding in vitro investigations. Errors in determining the therapeutically effective force system may result from the electrical measurement of the mechanical quantities by the sensor system and from the fixing of the archwire in therapeutic position. The precision of this fixing is influenced by displacements induced by elasticities and mechanical tensions in the measuring system. Calibration test series have shown the sensor system to have a margin of error of less than 2%. The displacements influencing precision fixing of the archwire were determined by means of a laser position measuring system. For a maximum orthodontic force of 1.5 N, they are 0.06 mm in the least favourable case. The resulting measuring accuracy was determined analytically or graphically, depending on the key parameters. Successful in vivo studies of the therapeutically applied force systems are to be expected on the basis of these results.

Mesh:

Year:  1998        PMID: 9577103     DOI: 10.1007/BF01340642

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  10 in total

1.  An experimental apparatus for the simulation of three-dimensional movements in orthodontics.

Authors:  C Bourauel; D Drescher; M Thier
Journal:  J Biomed Eng       Date:  1992-09

2.  Three-dimensional large displacement analysis of orthodontic appliances.

Authors:  J C DeFranco; H A Koenig; C J Burstone
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

3.  [The principles of two-teeth-mechanics in straight-wire-technique].

Authors:  R Meyer; H Wehrbein; B Schneider
Journal:  Prakt Kieferorthop       Date:  1991-11

4.  Segmented approach to simultaneous intrusion and space closure: biomechanics of the three-piece base arch appliance.

Authors:  B Shroff; S J Lindauer; C J Burstone; J B Leiss
Journal:  Am J Orthod Dentofacial Orthop       Date:  1995-02       Impact factor: 2.650

5.  Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I.

Authors:  N Rosarius; D Friedrich; R Fuhrmann; G Rau; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-10       Impact factor: 1.938

6.  Force systems from an ideal arch--large deflection considerations.

Authors:  H A Koenig; C J Burstone
Journal:  Angle Orthod       Date:  1989       Impact factor: 2.079

7.  Analysis of generalized curved beams for orthodontic applications.

Authors:  H A Koenig; C J Burstone
Journal:  J Biomech       Date:  1974-09       Impact factor: 2.712

8.  Force systems from an ideal arch.

Authors:  C J Burstone; H A Koenig
Journal:  Am J Orthod       Date:  1974-03

9.  Stress analysis of bone modeling response to rat molar orthodontics.

Authors:  T R Katona; N H Paydar; H U Akay; W E Roberts
Journal:  J Biomech       Date:  1995-01       Impact factor: 2.712

10.  Force systems from orthodontic appliances: an analytical and experimental comparison.

Authors:  H A Koenig; R Vanderby; D J Solonche; C J Burstone
Journal:  J Biomech Eng       Date:  1980-11       Impact factor: 2.097

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.