An experimental apparatus for the simulation of three-dimensional movements in orthodontics.

C Bourauel1, D Drescher, M Thier.   

Abstract

An apparatus for the study of three-dimensional force systems and the resulting movements during orthodontic treatment is presented. The instrument consists of two force-torque transducers which are capable of recording both forces and torques simultaneously, in all spatial directions. Each sensor has a measuring range of 15N (450 Nmm) and a resolution of 0.02 N (0.5 Nmm) and is mounted on a set of three translational and three rotational stages driven by stepping motors. Positioning accuracy is in the range of 1 micron and 0.01 degrees respectively. The apparatus is computer controlled and supported by comprehensive software.

Entities:  

Mesh:

Year:  1992        PMID: 1405553     DOI: 10.1016/0141-5425(92)90081-u

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  30 in total

1.  The influence of bracket design on frictional losses in the bracket/arch wire system.

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  Biomechanical analysis of arch-guided molar distalization when employing superelastic NiTi coil springs.

Authors:  R Schneevoigt; C Bourauel; W Harzer; L Eckardt
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

3.  Simulation of orthodontic tooth movements. A comparison of numerical models.

Authors:  C Bourauel; D Freudenreich; D Vollmer; D Kobe; D Drescher; A Jäger
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

4.  [A pseudoelastic NiTi uprighting spring for the molars--its design, biomechanical testing and clinical use].

Authors:  D Drescher; C Bourauel; M Thier
Journal:  Fortschr Kieferorthop       Date:  1992-10

5.  [The effect of molar position on the distalization behavior of indirect headgear].

Authors:  M Breier; C Bourauel; D Drescher; C W Schwarze
Journal:  Fortschr Kieferorthop       Date:  1995-07

6.  In vitro testing of a measuring system for in vivo recording of orthodontically applied forces and moments in the multiband technique. Part II.

Authors:  D Friedrich; N Rosarius; P Schwindke; G Rau; P Diedrich
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

7.  Material testing of reconditioned orthodontic brackets.

Authors:  S Reimann; A Rewari; L Keilig; F Widu; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2012-10-26       Impact factor: 1.938

8.  First order couples induced by nickel-titanium archwires featuring an electrochemically refined surface during simulated rotation of teeth.

Authors:  Leif Johannessen; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

9.  Friction behavior and other material properties of nickel-titanium and titanium-molybdenum archwires following electrochemical surface refinement.

Authors:  Miriam Julia Meier; Christoph Bourauel; Jan Roehlike; Susanne Reimann; Ludger Keilig; Bert Braumann
Journal:  J Orofac Orthop       Date:  2014-07-06       Impact factor: 1.938

10.  Symmetric and asymmetric expansion of molars using a Burstone-type transpalatal arch. Biomechanical and clinical analysis.

Authors:  Michaela Tsetsilas; Anna-Christin Konermann; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2015-09       Impact factor: 1.938

View more