Force systems from an ideal arch--large deflection considerations.

H A Koenig1, C J Burstone.   

Abstract

A sophisticated mathematical simulation is presented which allows for the consideration of large activations in orthodontic appliances and their effect upon the resulting force systems which are delivered to teeth. Effects of bracket/wire interaction are studied using this new tool. Previous studies of force systems from an ideal arch were redone with the new analysis in which the wire was either rigidly restrained or free to slide. The restraint of the wire produced large mesio-distal forces and increased the magnitude of the moments on each bracket. If the wire is free to slide, both large deflection and small deflection solutions give similar results. The relative force system M1/M2 fundamentally held true with large deflections and restraint; however, some differences were noted. The significance of allowing wire to slide in the bracket is discussed.

Mesh:

Substances:

Year:  1989        PMID: 2923317     DOI: 10.1043/0003-3219(1989)059<0011:FSFAIA>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  6 in total

1.  [Anterior tooth intrusion with the base arch: preactivation by tip-back bending or curvature?].

Authors:  H P Bantleon; F J Weiland; H Droschl
Journal:  Fortschr Kieferorthop       Date:  1991-06

2.  In vitro testing of a measuring system for in vivo recording of orthodontically applied forces and moments in the multiband technique. Part II.

Authors:  D Friedrich; N Rosarius; P Schwindke; G Rau; P Diedrich
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

3.  Combined intrusion and retraction generated by cantilevers with helical coils.

Authors:  B Melsen; V Konstantellos; M Lagoudakis; J Planert
Journal:  J Orofac Orthop       Date:  1997       Impact factor: 1.938

4.  Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires.

Authors:  Madhur Upadhyay; Raja Shah; Sachin Agarwal; Meenakshi Vishwanath; Po-Jung Chen; Takafumi Asaki; Donald Peterson
Journal:  J Vis Exp       Date:  2018-07-24       Impact factor: 1.355

5.  Force system generated by elastic archwires with vertical V bends: a three-dimensional analysis.

Authors:  Madhur Upadhyay; Raja Shah; Donald Peterson; Takafumi Asaki; Sumit Yadav; Sachin Agarwal
Journal:  Eur J Orthod       Date:  2017-04-01       Impact factor: 3.075

6.  An interview with Giorgio Fiorelli.

Authors:  Giorgio Fiorelli; Gidalti Bueno Linhares; Maurício Tatsuei Sakima; Renato Parsekian Martins; Wislei de Oliveira
Journal:  Dental Press J Orthod       Date:  2018 Sep-Oct
  6 in total