Literature DB >> 9572508

Fast accurate iterative reconstruction for low-statistics positron volume imaging.

A J Reader1, K Erlandsson, M A Flower, R J Ott.   

Abstract

A fast accurate iterative reconstruction (FAIR) method suitable for low-statistics positron volume imaging has been developed. The method, based on the expectation maximization-maximum likelihood (EM-ML) technique, operates on list-mode data rather than histogrammed projection data and can, in just one pass through the data, generate images with the same characteristics as several ML iterations. Use of list-mode data preserves maximum sampling accuracy and implicitly ignores lines of response (LORs) in which no counts were recorded. The method is particularly suited to systems where sampling accuracy can be lost by histogramming events into coarse LOR bins, and also to sparse data situations such as fast whole-body and dynamic imaging where sampling accuracy may be compromised by storage requirements and where reconstruction time can be wasted by including LORs with no counts. The technique can be accelerated by operating on subsets of list-mode data which also allows scope for simultaneous data acquisition and iterative reconstruction. The method is compared with a standard implementation of the EM-ML technique and is shown to offer improved resolution, contrast and noise properties as a direct result of using improved spatial sampling, limited only by hardware specifications.

Entities:  

Mesh:

Year:  1998        PMID: 9572508     DOI: 10.1088/0031-9155/43/4/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

2.  Fast GPU-based computation of spatial multigrid multiframe LMEM for PET.

Authors:  Moulay Ali Nassiri; Jean-François Carrier; Philippe Després
Journal:  Med Biol Eng Comput       Date:  2015-04-08       Impact factor: 2.602

3.  NanoPET imaging of [(18)F]fluoromisonidazole uptake in experimental mouse tumours.

Authors:  Matthias T Wyss; Michael Honer; Pius A Schubiger; Simon M Ametamey
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-10-29       Impact factor: 9.236

Review 4.  Computed tomography dose optimisation in cystic fibrosis: A review.

Authors:  Helena Ferris; Maria Twomey; Fiachra Moloney; Siobhan B O'Neill; Kevin Murphy; Owen J O'Connor; Michael Maher
Journal:  World J Radiol       Date:  2016-04-28

5.  Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET.

Authors:  Dan J Kadrmas; M Bugrahan Oktay; Michael E Casey; James J Hamill
Journal:  IEEE Trans Nucl Sci       Date:  2012-10       Impact factor: 1.679

Review 6.  Computed tomography in cystic fibrosis lung disease: a focus on radiation exposure.

Authors:  Stella Joyce; Brian W Carey; Niamh Moore; David Mullane; Michael Moore; Mark F McEntee; Barry J Plant; Michael M Maher; Owen J O'Connor
Journal:  Pediatr Radiol       Date:  2021-03-20

Review 7.  Update on time-of-flight PET imaging.

Authors:  Suleman Surti
Journal:  J Nucl Med       Date:  2014-12-18       Impact factor: 10.057

8.  The imaging performance of a LaBr3-based PET scanner.

Authors:  M E Daube-Witherspoon; S Surti; A Perkins; C C M Kyba; R Wiener; M E Werner; R Kulp; J S Karp
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

Review 9.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

10.  A theoretical model for EM-ML reconstruction algorithms applied to rotating PET scanners.

Authors:  A Iriarte; C O S Sorzano; J M Carazo; J L Rubio; R Marabini
Journal:  Phys Med Biol       Date:  2009-03-05       Impact factor: 3.609

View more