Literature DB >> 9571618

Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams.

P Francescon1, S Cora, C Cavedon, P Scalchi, S Reccanello, F Colombo.   

Abstract

The dosimetry of the fields usually employed in radiosurgery requires the use of small detectors to measure Total Scatter Factor (Sc,p), Tissue Maximum Ratio (TMR), Percentage Depth Dose (PDD), and Off Axis Ratio (OAR). In this paper new dosimeters are investigated: a new type of radiochromic film, a micro parallel-plate chamber (filled with both air and tetramethylsilane, TMS), MOSFETs, and TLD-800 microcubes. Their behavior has been compared with the response of radiographic film and with the values obtained with BEAM Monte Carlo simulation. The experimental data confirm that dosimetry with radiochromic films and TLDs gives consistent results for all beam diameters. The parallel-plate micro chamber underestimates the Sc,p for the smallest field diameters (4.4 mm and 6.7 mm); MOSFETs show an over-estimation for the Sc,p of the 4.4 mm, 6.7 mm, and 10.5 mm field diameters. BEAM Monte Carlo simulation employing a parallel beam and a standard 6 MV x-ray spectrum has been used to obtain a correction factor as a function of the field size for both the parallel-plate micro chamber and MOSFETs. High accuracy measurements of PDD and TMR have been made in a water phantom both with radiochromic film and with the micro parallel-plate chamber and have been compared with the data computed by BEAM Monte Carlo simulation. The latter dosimeter is preferred because of the quicker and simpler use and because it gives immediate readout. Measurements of OAR made with radiochromic films and with radiographic films give differences in the 80%-20% penumbra width within 0.6 mm for field diameters ranging from 4.4 mm to 19 mm.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9571618     DOI: 10.1118/1.598227

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  The change of response of ionization chambers in the penumbra and transmission regions: impact for IMRT verification.

Authors:  D González-Castaño; J Pena; F Sánchez-Doblado; G H Hartmann; F Gómez; A Leal
Journal:  Med Biol Eng Comput       Date:  2007-09-08       Impact factor: 2.602

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam.

Authors:  Kyohei Fukata; Satoru Sugimoto; Chie Kurokawa; Akito Saito; Tatsuya Inoue; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2018-04-04

4.  Polarity effect in commercial ionization chambers used in photon beams with small fields.

Authors:  Tetsunori Shimono; Kichiro Koshida; Hidekazu Nambu; Kosuke Matsubara; Hiroshi Takahashi; Hiroshi Okuda
Journal:  Radiol Phys Technol       Date:  2008-12-18

5.  Variation of kQclin,Qmsr (fclin,fmsr) for the small-field dosimetric parameters percentage depth dose, tissue-maximum ratio, and off-axis ratio.

Authors:  Paolo Francescon; Sam Beddar; Ninfa Satariano; Indra J Das
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

6.  Dosimetric comparison of linear accelerator-based stereotactic radiosurgery systems.

Authors:  S D Sharma; Sudhir Kumar; S S Dagaonkar; Geetika Bisht; S Dayanand; Reena Devi; S S Deshpande; S Chaudhary; B C Bhatt; S Kannan
Journal:  J Med Phys       Date:  2007-01

7.  Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study.

Authors:  Fadil Akyol; Neslihan Sarigul; Mete Yeginer; Yagiz Yedekci; Haluk Utku
Journal:  J Med Phys       Date:  2019 Jan-Mar

8.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.