Biomechanical characterization of osseointegration: an experimental in vivo investigation in the beagle dog.

R Brånemark1, L O Ohrnell, R Skalak, L Carlsson, P I Brånemark.   

Abstract

This study reports the results of torsion tests, pull-out tests, and lateral loading tests on osseointegrated commercially pure titanium fixtures. The tests were performed in vivo on six beagle dogs. Three fixtures, each with a diameter of 3.7 mm, were installed bilaterally in the tibia of each animal. The mean maximal pull-out load was 1.55 kN (n = 4), the mean maximal lateral transverse load was 0.21 kN (n = 2), the mean maximal lateral axial load was 0.18 kN (n = 2), the mean breakpoint torque was 0.31 Nm (n = 3), and the mean maximal torque was 0.43 Nm (n = 3). The torsion test revealed an almost immediate plastic deformation of the interface between the implant and bone; this indicates that although the contact between the bone and the implant is close, there is no strong bond, at least not in shear. The major transfer of load from the implant to the surrounding bone tissue must therefore depend on the design of the implant. A histological evaluation with measurements of the amount of bone in contact with the fixtures was performed. By the use of the histological and mechanical data, it is possible to estimate shear stresses in bone tissue (pull-out test) and in the interface (torque test). The mean maximal shear stress in bone tissue in the pull-out tests was 100 MPa (n = 4); the mean shear stress in the interface was 4.3 MPa (n = 3) in the torsion tests at the breakpoint torque and was 6.0 MPa (n = 3) at the maximal torque. It was also possible to estimate the shear modulus of elasticity in the pull-out and torque tests. The mean shear modulus in pull-out was 119 MPa (n = 4), and the mean apparent shear modulus in torsion was 9 kPa (n = 3) for an assumed interface thickness of 100 nm and was 86 kPa (n = 3) for an assumed interface thickness of 1,000 nm.

Entities:  

Mesh:

Year:  1998        PMID: 9565075     DOI: 10.1002/jor.1100160111

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  12 in total

1.  Porous composite prosthetic pylon for integration with skin and bone.

Authors:  Mark Pitkin; Grigory Raykhtsaum; John Pilling; Oleg V Galibin; Mikhail V Protasov; Julie V Chihovskaya; Irina G Belyaeva; Miralda I Blinova; Natalia M Yudintseva; Igor L Potokin; George P Pinaev; Vladimir Moxson; Volodimir Duz
Journal:  J Rehabil Res Dev       Date:  2007

2.  A novel in vivo method for quantifying the interfacial biochemical bond strength of bone implants.

Authors:  Young-Taeg Sul; Carina Johansson; Tomas Albrektsson
Journal:  J R Soc Interface       Date:  2009-04-15       Impact factor: 4.118

Review 3.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

4.  An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model.

Authors:  Young Jae Moon; Jong-Kil Kim; Hong-Geun Oh; Ji-Hun Kang; Gun-Joo Park; Kwang-Bok Lee
Journal:  J Vis Exp       Date:  2017-05-31       Impact factor: 1.355

5.  Mineralizing Coating on 3D Printed Scaffolds for the Promotion of Osseointegration.

Authors:  Abshar Hasan; Romain Bagnol; Robert Owen; Arsalan Latif; Hassan M Rostam; Sherif Elsharkawy; Felicity R A J Rose; José Carlos Rodríguez-Cabello; Amir M Ghaemmaghami; David Eglin; Alvaro Mata
Journal:  Front Bioeng Biotechnol       Date:  2022-06-27

6.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

7.  On the way to total integration of prosthetic pylon with residuum.

Authors:  Mark Pitkin
Journal:  J Rehabil Res Dev       Date:  2009

Review 8.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

9.  The effect of bone marrow-derived stem cells associated with platelet-rich plasma on the osseointegration of immediately placed implants.

Authors:  Roberta-Targa Stramandinoli-Zanicotti; Laurindo-Moacir Sassi; Carmen-Lucia-Kuniyoshi Rebelatto; Lidiane M Boldrine-Leite; Paulo-Roberto Brofman; Andre-Lopes Carvalho
Journal:  J Clin Exp Dent       Date:  2021-01-01

10.  The improved biological performance of a novel low elastic modulus implant.

Authors:  Lei Shi; Lei Shi; Ling Wang; Yonghong Duan; Wei Lei; Zhen Wang; Jing Li; Xiangli Fan; Xiaokang Li; Shujun Li; Zheng Guo
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.