Literature DB >> 9564397

Anaesthesia circuits, humidity output, and mucociliary structure and function.

R D Branson1, R S Campbell, K Davis, D T Porembka.   

Abstract

We compared the effects of humidity delivered by the circle system at low fresh gas flows (FGF) with a conventional two-limb and coaxial circuit on the structure and function of the tracheobronchial epithelium in dogs. Animals were anaesthetized and mechanically ventilated using an anaesthesia ventilator to maintain normocarbia. Group I (control) animals received a FGF equal to the required minute ventilation mimicking an open circuit technique. Group II and III animals had FGF set at 20% of the required minute ventilation. Group II used a two-limb circuit and Group III used a coaxial circuit. Relative humidity and temperature of inspired gases were measured at baseline and hourly afterwards. In the first experiment, biopsies of the tracheobronchial tree were obtained bronchoscopically at baseline and then hourly for six hours. Microscopic examination of these samples allowed calculation of mean ciliary length. In the second experiment, tracheal mucus flow velocity (TMFV) was measured at baseline and hourly afterward, using a cinebroncho-fibrescopic method. Delivered absolute humidity was greatest with low FGF and the coaxial circuit, followed by low FGF and a conventional circuit, and high FGF (15 +/- 1.4 vs 9 +/- 0.8 vs 5 +/- 0.4 mg H2O, P < 0.01) after two hours. Mean cilia length (micron) and TMFV (mm/min) fell during the first hour in all three groups. At hour two TMFV returned to baseline in Group III and was significantly greater than Groups I and II (0.8 +/- 0.4 vs 8.6 +/- 1.1 vs 15.4 +/- 2.1, P < 0.001). Mean ciliary length demonstrated a similar pattern with reductions from baseline in all three groups for the first two hours. Groups II and III had an increase in cilia length beginning at hour three and were both significantly greater than Group I at hours 3 through 6 (1.3 +/- 0.5 vs 3.2 +/- 1.1 vs 4.2 +/- 0.8, P < 0.001). Alterations in tracheobronchial structure and function result from exposure to dry gases and are amplified by the duration of exposure. Our findings suggest a minimum of 12 to 15 mg H2O/l is necessary to prevent these alterations. In this study, the combination of low FGF and a coaxial anaesthesia circuit reached this minimum threshold more quickly than a conventional two-limb circuit.

Entities:  

Mesh:

Year:  1998        PMID: 9564397     DOI: 10.1177/0310057X9802600208

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  7 in total

1.  Efficacy of a heat and moisture exchanger in inhalation anesthesia at two different flow rates.

Authors:  Koichi Yamashita; Takeshi Yokoyama; Hidehiro Abe; Tomoki Nishiyama; Masanobu Manabe
Journal:  J Anesth       Date:  2007-01-30       Impact factor: 2.078

2.  The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia.

Authors:  Chih-Cherng Lu; Shung-Tai Ho; Wen-Jinn Liaw; Ruei-Ming Chen; Ta-Liang Chen; Chung-Yuan Lin
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

Review 3.  Humidification and heating of inhaled gas in patients with artificial airway. A narrative review.

Authors:  Gustavo Adrián Plotnikow; Matias Accoce; Emiliano Navarro; Norberto Tiribelli
Journal:  Rev Bras Ter Intensiva       Date:  2018-03

4.  The effect of benzydamine hydrochloride on preventing postoperative sore throat after total thyroidectomy: a randomized-controlled trial.

Authors:  Doyeon Kim; Heejoon Jeong; Jihye Kwon; Sehee Kang; Bobae Han; Eun Kyung Lee; Sangmin M Lee; Ji Won Choi
Journal:  Can J Anaesth       Date:  2019-04-16       Impact factor: 5.063

5.  The effect of the humidifier on sore throat and cough after thyroidectomy.

Authors:  Tae Hyeng Jung; Jeong-Ho Rho; Jin Hwan Hwang; Jong-Hyuk Lee; Seung-Cheol Cha; Seong Chang Woo
Journal:  Korean J Anesthesiol       Date:  2011-12-20

6.  The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.

Authors:  Sergius A R de Oliveira; Lorena M C Lucio; Norma S P Modolo; Yoko Hayashi; Mariana G Braz; Lídia R de Carvalho; Leandro G Braz; José Reinaldo C Braz
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

7.  Effects of different fresh gas flows and different anesthetics on airway temperature and humidity in surgical patients: a prospective observational study.

Authors:  Irem Gumus Ozcan; Ozkan Onal; Aysun Ozdemirkan; Ali Saltali; Mehmet Sari
Journal:  Med Gas Res       Date:  2022 Jul-Sep
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.