Literature DB >> 17285414

Efficacy of a heat and moisture exchanger in inhalation anesthesia at two different flow rates.

Koichi Yamashita1, Takeshi Yokoyama, Hidehiro Abe, Tomoki Nishiyama, Masanobu Manabe.   

Abstract

In general anesthesia with endotracheal intubation, a circle system with a heat and moisture exchanger (HME) and a low total flow is often used to prevent hypothermia and to maintain inspired gas humidity. The purpose of the present study was to compare the inspired gas humidity and body temperature, in general anesthesia with or without an HME at two different total flow rates. Eighty patients (American Society of Anesthesiologists [ASA] I or II) scheduled to undergo either orthopedic or head and neck surgery were studied. They were divided into four groups, of 20 patients each: total flow of 2 lxmin(-1) with (group HME2L) or without (group 2L) HME, and a total flow of 4 lxmin(-1) with (group HME4L) or without (group 4L) HME. The relative and absolute humidity and pharyngeal and inspired gas temperatures were measured for 2 h after endotracheal intubation. The relative humidity was not significantly different among groups 2L, HME2L, and HME4L. Group 4L had significantly lower absolute humidity than group 2L. The pharyngeal temperature did not decrease significantly for 2 h in any of the groups. During general anesthesia with a total flow of 2 lxmin(-1) in 2 h, HME might not be necessary, while with a total flow of 4 lxmin(-1), HME could be useful to maintain inspired gas humidity.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17285414     DOI: 10.1007/s00540-006-0442-5

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  13 in total

1.  Core temperature monitoring with new ventilatory devices.

Authors:  Takashi Matsukawa; Takahisa Goto; Makoto Ozaki; Daniel I Sessler; Akira Takeuchi; Tomoki Nishiyama; Teruo Kumazawa
Journal:  Anesth Analg       Date:  2003-06       Impact factor: 5.108

2.  Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire.

Authors:  H Miyao; T Hirokawa; K Miyasaka; T Kawazoe
Journal:  Crit Care Med       Date:  1992-05       Impact factor: 7.598

Review 3.  Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa.

Authors:  R Williams; N Rankin; T Smith; D Galler; P Seakins
Journal:  Crit Care Med       Date:  1996-11       Impact factor: 7.598

4.  The effect of heat and moisture exchanger and gas flow on humidity and temperature in a circle anaesthetic system.

Authors:  R Poopalalingam; M H Goh; Y W Chan
Journal:  Singapore Med J       Date:  2002-11       Impact factor: 1.858

5.  The circle system as a humidifier.

Authors:  J P Bengtson; A Bengtson; O Stenqvist
Journal:  Br J Anaesth       Date:  1989-10       Impact factor: 9.166

6.  Humidity of anaesthetic gases with respect to low flow anaesthesia.

Authors:  P P Kleemann
Journal:  Anaesth Intensive Care       Date:  1994-08       Impact factor: 1.669

7.  Nephrotoxicity of sevoflurane versus desflurane anesthesia in volunteers.

Authors:  E I Eger; D D Koblin; T Bowland; P Ionescu; M J Laster; Z Fang; D Gong; J Sonner; R B Weiskopf
Journal:  Anesth Analg       Date:  1997-01       Impact factor: 5.108

8.  The effect of heat and moisture exchanger on humidity and body temperature in a low-flow anaesthesia system.

Authors:  A Johansson; D Lundberg; H H Luttropp
Journal:  Acta Anaesthesiol Scand       Date:  2003-05       Impact factor: 2.105

9.  Humidity and temperature changes during low flow and closed system anaesthesia.

Authors:  J A Aldrete; P Cubillos; D Sherrill
Journal:  Acta Anaesthesiol Scand       Date:  1981-08       Impact factor: 2.105

10.  Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group.

Authors:  A Kurz; D I Sessler; R Lenhardt
Journal:  N Engl J Med       Date:  1996-05-09       Impact factor: 91.245

View more
  3 in total

1.  The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.

Authors:  Sergius A R de Oliveira; Lorena M C Lucio; Norma S P Modolo; Yoko Hayashi; Mariana G Braz; Lídia R de Carvalho; Leandro G Braz; José Reinaldo C Braz
Journal:  PLoS One       Date:  2017-01-27       Impact factor: 3.240

2.  Effects of different fresh gas flows and different anesthetics on airway temperature and humidity in surgical patients: a prospective observational study.

Authors:  Irem Gumus Ozcan; Ozkan Onal; Aysun Ozdemirkan; Ali Saltali; Mehmet Sari
Journal:  Med Gas Res       Date:  2022 Jul-Sep

3.  Perioperative hypothermia during surgery: is warming humidification a complete solution?

Authors:  Antonio M Esquinas
Journal:  Korean J Anesthesiol       Date:  2014-03
  3 in total