Literature DB >> 9559379

Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique.

O Rodevand1, R Bjornerheim, S Aakhus, J Kjekshus.   

Abstract

UNLABELLED: Three-dimensional (3D) echocardiography may overcome the problems with inadequate accuracy and reproducibility of 2D volume measurements of the left ventricle. AIMS: To establish the in vitro accuracy and reproducibility of two new methods for 3D echocardiographic volume determination as compared to biplane measurements.
METHODS: Validation of volume measurements by a multiplane 3D method was performed on asymmetric latex phantoms (n = 8, true volumes 45-304 ml) using rotational acquisition of 90 image planes. Porcine agarose-filled asymmetrical left ventricles (n = 7, true volumes 34-280 ml) were measured by the same multiplane 3D method based on images acquired by probe rotation axis perpendicular (A) and parallel (B) to the ventricular long axis. Ventricular volumes were also obtained by a simplified 3D system using only the three standard apical views (C) and by the ordinary biplane Simpson's method (D).
RESULTS: On latex phantoms systematic deviation from true volumes by multiplane 3D was less than 2%, and 95% variability of individual measurements from this mean was +/- 4.9%. For accuracy on left ventricles, systematic bias was small with all the methods (< 5%), but 95% variability of individual measurements was +/- 9.0%, 15.4%, 18.8% and 41.3% of true volumes for methods A-D respectively. Corresponding results in the same range were obtained for inter- and intraobserver variability.
CONCLUSION: Individual in vitro volume estimates of left ventricles are of similar quality using apical multiplane or apical triplane 3D echocardiography. Both methods were superior to the ordinary apical biplane method, but inferior to multiplane 3D method with the probe directed perpendicular to the ventricular long axis.

Entities:  

Mesh:

Year:  1998        PMID: 9559379     DOI: 10.1023/a:1005820303511

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  17 in total

Review 1.  Dynamic three-dimensional echocardiography: methods and clinical potential.

Authors:  N G Pandian; J Roelandt; N C Nanda; L Sugeng; Q L Cao; J Azevedo; S L Schwartz; M A Vannan; A Ludomirski; G Marx
Journal:  Echocardiography       Date:  1994-05       Impact factor: 1.724

2.  The log transformation is special.

Authors:  O N Keene
Journal:  Stat Med       Date:  1995-04-30       Impact factor: 2.373

Review 3.  Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms.

Authors:  N B Schiller; P M Shah; M Crawford; A DeMaria; R Devereux; H Feigenbaum; H Gutgesell; N Reichek; D Sahn; I Schnittger
Journal:  J Am Soc Echocardiogr       Date:  1989 Sep-Oct       Impact factor: 5.251

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Three dimensional reconstruction of the heart with rotational acquisition: methods and clinical applications.

Authors:  A Salustri; J Roelandt
Journal:  Br Heart J       Date:  1995-05

6.  Three-dimensional echocardiographic measurement of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography.

Authors:  P M Sapin; K D Schroeder; M D Smith; A N DeMaria; D L King
Journal:  J Am Coll Cardiol       Date:  1993-11-01       Impact factor: 24.094

7.  Three-dimensional echocardiography. Advances for measurement of ventricular volume and mass.

Authors:  D L King; A S Gopal; A M Keller; P M Sapin; K M Schröder
Journal:  Hypertension       Date:  1994-01       Impact factor: 10.190

8.  Three-dimensional echocardiographic volume computation: in vitro comparison to standard two-dimensional echocardiography.

Authors:  K M Schröder; P M Sapin; D L King; M D Smith; A N DeMaria
Journal:  J Am Soc Echocardiogr       Date:  1993 Sep-Oct       Impact factor: 5.251

9.  A new method for echocardiographic computerized three-dimensional reconstruction of left ventricular endocardial surface: in vitro accuracy and clinical repeatability of volumes.

Authors:  S Aakhus; J Maehle; K Bjoernstad
Journal:  J Am Soc Echocardiogr       Date:  1994 Nov-Dec       Impact factor: 5.251

10.  Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer.

Authors:  J R Roelandt; F J ten Cate; W B Vletter; M A Taams
Journal:  J Am Soc Echocardiogr       Date:  1994 May-Jun       Impact factor: 5.251

View more
  1 in total

1.  Left atrial volumes assessed by three- and two-dimensional echocardiography compared to MRI estimates.

Authors:  O Rodevan; R Bjornerheim; M Ljosland; J Maehle; H J Smith; H Ihlen
Journal:  Int J Card Imaging       Date:  1999-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.