Literature DB >> 7840984

A new method for echocardiographic computerized three-dimensional reconstruction of left ventricular endocardial surface: in vitro accuracy and clinical repeatability of volumes.

S Aakhus1, J Maehle, K Bjoernstad.   

Abstract

This study evaluates the in vitro accuracy and clinical repeatability of volumes derived by a new algorithm for three-dimensional reconstruction of cavity surfaces based on echocardiographic apical images obtained by probe rotation. The accuracy of the method was tested in latex phantoms (true volumes, 32 to 349 cm3) with (n = 9) or without (n = 9) rotational symmetry around the midcavitary long axis. Repeatability of left ventricular volumes was assessed in subjects without (n = 5) or with (n = 10) myocardial disease. Estimated phantom volumes obtained from four (three) imaging planes were close to true volumes with a mean difference +/- SD of 0 +/- 2 (2 +/- 3) cm3 in symmetric and 1 +/- 3 (4 +/- 4) cm3 in asymmetric objects. Biplane and single-plane volume estimates were less accurate. Interobserver and intraobserver repeatability of three-dimensional left ventricular volumes was good for analysis (coefficients of variation: 3.5% to 6.2%) and was lower for recording (coefficients of variation: 7.4% to 10.9%). Hence the present algorithm reproduces volumes of symmetric and deformed in vitro objects accurately over a wide range of size and shape, and it produces repeatable left ventricular volumes in the clinical situation.

Entities:  

Mesh:

Year:  1994        PMID: 7840984     DOI: 10.1016/s0894-7317(14)80079-5

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  6 in total

1.  Left atrial volumes assessed by three- and two-dimensional echocardiography compared to MRI estimates.

Authors:  O Rodevan; R Bjornerheim; M Ljosland; J Maehle; H J Smith; H Ihlen
Journal:  Int J Card Imaging       Date:  1999-10

2.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

3.  Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique.

Authors:  O Rodevand; R Bjornerheim; S Aakhus; J Kjekshus
Journal:  Int J Card Imaging       Date:  1998-02

4.  Effects of glucose-insulin-potassium infusion on chronic ischaemic left ventricular dysfunction.

Authors:  V K Khoury; B Haluska; J Prins; T H Marwick
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

5.  Left atrial volume assessed by transthoracic three dimensional echocardiography and magnetic resonance imaging: dynamic changes during the heart cycle in children.

Authors:  T Poutanen; A Ikonen; P Vainio; E Jokinen; T Tikanoja
Journal:  Heart       Date:  2000-05       Impact factor: 5.994

6.  Feasibility of creating estimates of left ventricular flow-volume dynamics using echocardiography.

Authors:  Emil Söderqvist; Peter Cain; Britta Lind; Reidar Winter; Jacek Nowak; Lars-Ake Brodin
Journal:  Cardiovasc Ultrasound       Date:  2006-10-31       Impact factor: 2.062