Literature DB >> 9556745

Assessment of myocardial perfusion by intermittent harmonic power Doppler using SonoVue, a new ultrasound contrast agent.

A Broillet1, J Puginier, R Ventrone, M Schneider.   

Abstract

RATIONALE AND
OBJECTIVES: The authors evaluated the potential of SonoVue, a new echo contrast agent, for the detection of myocardial perfusion abnormalities using intermittent harmonic power Doppler (IHPD) imaging and different pulse repetition frequencies (PRFs).
METHODS: Experiments were performed in vitro (in a tissue-mimicking phantom) and in vivo (in minipigs) in harmonic power Doppler using an ATL HDI 3000 with second harmonic software. SonoVue was injected intravenously in an auricular vein in bolus (dose range 0.01-0.05 mL/kg) in closed-chest animals or as an infusion (rate = 0.1 mL/kg/minute) in open-chest minipigs with reversible left anterior descending coronary artery (LAD) occlusion. The animals were imaged using IHPD gated on the electrocardiogram at end-systole (pulsing interval at each cardiac cycle). The efficacy of SonoVue was evaluated at six PRFs from 500 to 6000 Hz either qualitatively using a subjective scoring system or quantitatively using a digital image analyzer.
RESULTS: SonoVue at a dose of 0.01 mL/kg produced a strong and homogeneous myocardial opacification in IHPD. Higher doses prolonged the duration of the contrast effect. Varying the PRF allowed the discrimination of flow velocities in vitro and the detection of perfusion differences within the myocardium during transient LAD occlusion and during immediate reperfusion in vivo. Low PRFs were particularly useful to differentiate the ischemic bed from the healthy one during LAD occlusion. The high flows caused by coronary hyperemia during immediate reperfusion were detected clearly in the reperfused area at high PRFs.
CONCLUSIONS: SonoVue is a promising agent for myocardial opacification studies using IHPD. The latter imaging modality is particularly well suited for blood flow detection in tissues. Varying the PRF provides additional information on flow velocity and improves the detection of perfusion differences in the myocardium.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9556745     DOI: 10.1097/00004424-199804000-00003

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  11 in total

Review 1.  Added value of contrast echocardiography in assessing myocardial viability.

Authors:  A Nagy; F L Dini; D Rovai
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

2.  Fourier phase and amplitude analysis for automated objective evaluation of myocardial contrast echocardiograms.

Authors:  Raffi Bekeredjian; Thomas Hilbel; Arthur Filusch; Alexander Hansen; Andreas Benz; Joerg Zehelein; Helmut F Kuecherer
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

3.  Assessment of myocardial perfusion abnormalities by intravenous myocardial contrast echocardiography with harmonic power Doppler imaging: comparison with positron emission tomography.

Authors:  T Muro; T Hozumi; H Watanabe; H Yamagishi; M Yoshiyama; K Takeuchi; J Yoshikawa
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

4.  Potential pitfalls of visualization of myocardial perfusion by myocardial contrast echocardiography with harmonic gray scale B-mode and power Doppler imaging.

Authors:  Hisashi Masugata; Kazushi Yukiiri; Yuichiro Takagi; Koji Ohmori; Katsufumi Mizushige; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2004-04       Impact factor: 2.357

5.  Novel quantitative assessment of myocardial perfusion by harmonic power Doppler imaging during myocardial contrast echocardiography.

Authors:  S Yamada; K Komuro; T Mikami; N Kudo; H Onozuka; K Goto; S Fujii; K Yamamoto; A Kitabatake
Journal:  Heart       Date:  2005-02       Impact factor: 5.994

6.  Contrast-enhanced ultrasound imaging of prostate cancer.

Authors:  Ethan J Halpern
Journal:  Rev Urol       Date:  2006

7.  Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques.

Authors:  K Hirooka; K Miyatake; A Hanatani; K Komamura; S Nakatani; Y Yasumura; M Yamagishi
Journal:  Int J Card Imaging       Date:  2000-08

8.  Changes in transmural distribution of myocardial perfusion assessed by quantitative intravenous myocardial contrast echocardiography in humans.

Authors:  S Fukuda; T Muro; T Hozumi; H Watanabe; K Shimada; M Yoshiyama; K Takeuchi; J Yoshikawa
Journal:  Heart       Date:  2002-10       Impact factor: 5.994

9.  Feasibility of continuous venous infusion of SonoVue for qualitative assessment of reversible coronary perfusion defects in stress myocardial contrast echocardiography.

Authors:  Gabriel W Yip; Krishnaswamy Chandrasekaran; Todd D Miller; Mary E Hagen; Andrew P Langins; Bijoy K Khandheria
Journal:  Int J Cardiovasc Imaging       Date:  2003-12       Impact factor: 2.357

10.  Restored perfusion and reduced inflammation in the infarcted heart after grafting stem cells with a hyaluronan-based scaffold.

Authors:  Claudio Muscari; Francesca Bonafè; Sofia Martin-Suarez; Simond Valgimigli; Sabrina Valente; Emanuela Fiumana; Federico Fiorelli; Giuseppe Rubini; Carlo Guarnieri; Claudio Marcello Caldarera; Ombretta Capitani; Giorgio Arpesella; Gianandrea Pasquinelli
Journal:  J Cell Mol Med       Date:  2013-03-11       Impact factor: 5.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.