Literature DB >> 14690186

Feasibility of continuous venous infusion of SonoVue for qualitative assessment of reversible coronary perfusion defects in stress myocardial contrast echocardiography.

Gabriel W Yip1, Krishnaswamy Chandrasekaran, Todd D Miller, Mary E Hagen, Andrew P Langins, Bijoy K Khandheria.   

Abstract

OBJECTIVE: To study the feasibility of continuous intravenous SonoVue contrast echocardiography for qualitative assessment of reversible myocardial perfusion in dipyridamole stress tests.
METHODS: Eleven patients (10 male and 1 female, mean age 66 years) with a history of chest pain and a clinical indication for stress sestamibi single photon emission computed tomography (SPECT) underwent concurrent SonoVue 99mTc myocardial contrast echocardiography (MCE).
RESULTS: Of the total 176 segments obtained, 53 (30%) were regarded as indeterminate, 39 (22%) as discordant, and 84 (48%) as concordant between MCE and SPECT imaging. Two patients had abnormal SPECT results. The overall feasibility and specificity of MCE were 70 and 74%, respectively. The concordant (p = 0.59) and discordant (p = 0.55) segments were comparable with either MCE technique. However, continuous low-mechanical-index imaging produced fewer indeterminate segments (17 segments, 32%) than intermittent harmonic B-mode imaging (36 segments, 68%) (p = 0.04). Significantly more indeterminate segments were found in the left anterior descending artery territory. However, the overall concordance was similar (p = 0.5) in all three coronary artery territories. The concordance and discordance rates at different left ventricular levels (i.e., basal, mid, and apical) were similar (p = 0.50 and 0.08, respectively).
CONCLUSION: Continuous-infusion SonoVue contrast echocardiography is feasible, with high specificity, for detecting myocardial perfusion defects as assessed by dipyridamole SPECT.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14690186     DOI: 10.1023/b:caim.0000004263.46151.9d

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  15 in total

1.  Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography.

Authors:  S Shimoni; W A Zoghbi; F Xie; D Kricsfeld; S Iskander; L Gobar; I A Mikati; J Abukhalil; M S Verani; E L O'Leary; T R Porter
Journal:  J Am Coll Cardiol       Date:  2001-03-01       Impact factor: 24.094

2.  Executive Summary of The Third Report of The National Cholesterol Education Program (NCEP) Expert Panel on Detection, Evaluation, And Treatment of High Blood Cholesterol In Adults (Adult Treatment Panel III).

Authors: 
Journal:  JAMA       Date:  2001-05-16       Impact factor: 56.272

3.  Power doppler harmonic imaging: a feasibility study of a new technique for the assessment of myocardial perfusion.

Authors:  R Senior; S Kaul; P Soman; A Lahiri
Journal:  Am Heart J       Date:  2000-02       Impact factor: 4.749

4.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

Authors:  K Wei; A R Jayaweera; S Firoozan; A Linka; D M Skyba; S Kaul
Journal:  Circulation       Date:  1998-02-10       Impact factor: 29.690

5.  Assessment of myocardial perfusion by intermittent harmonic power Doppler using SonoVue, a new ultrasound contrast agent.

Authors:  A Broillet; J Puginier; R Ventrone; M Schneider
Journal:  Invest Radiol       Date:  1998-04       Impact factor: 6.016

6.  Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging.

Authors:  T R Porter; F Xie; M Silver; D Kricsfeld; E Oleary
Journal:  J Am Coll Cardiol       Date:  2001-03-01       Impact factor: 24.094

7.  Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging.

Authors:  S K Heinle; J Noblin; P Goree-Best; A Mello; G Ravad; S Mull; P Mammen; P A Grayburn
Journal:  Circulation       Date:  2000-07-04       Impact factor: 29.690

8.  Detection of myocardial perfusion in multiple echocardiographic windows with one intravenous injection of microbubbles using transient response second harmonic imaging.

Authors:  T R Porter; S Li; D Kricsfeld; R W Armbruster
Journal:  J Am Coll Cardiol       Date:  1997-03-15       Impact factor: 24.094

9.  Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography.

Authors:  S Kaul; R Senior; H Dittrich; U Raval; R Khattar; A Lahiri
Journal:  Circulation       Date:  1997-08-05       Impact factor: 29.690

10.  Regional heterogeneity on myocardial contrast echocardiography without severe obstructive coronary artery disease.

Authors:  D S Bach; D W Muller; J Cheirif; W F Armstrong
Journal:  Am J Cardiol       Date:  1995-05-15       Impact factor: 2.778

View more
  2 in total

1.  Vascular lesions and s-thrombomodulin concentrations from auricular arteries of rabbits infused with microbubble contrast agent and exposed to pulsed ultrasound.

Authors:  James F Zachary; James P Blue; Rita J Miller; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

2.  Spatial distribution of right ventricular perfusion abnormalities following acute right coronary artery occlusion: a study by myocardial contrast echocardiography and blue dye staining.

Authors:  Hisashi Masugata; Shoichi Senda; Norihiro Fujita; Katsufumi Mizushige; Koji Ohmori; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2005-12       Impact factor: 2.357

  2 in total