Wear in uncemented porous and cemented polyethylene sockets: a randomised, radiostereometric study.

I Onsten1, A S Carlsson, J Besjakov.   

Abstract

We used radiostereometric analysis to compare wear rates between uncemented porous sockets and cemented all-polyethylene sockets in a series of 102 hips randomised for either a Harris-Galante or a Charnley cup. Wear was evaluated in 95 hips at a mean of five years (2 to 7). All hips had a cemented, 22 mm head mono-bloc Charnley stem. The mean annual wear rate was 0.09 mm in the Charnley sockets and 0.10 mm in the Harris-Galante sockets, with no statistically significant differences in wear, migration or rotation. We conclude that, up to five years, the wear characteristics of the modular and porous Harris-Galante socket resemble that of the Charnley socket.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9546474     DOI: 10.1302/0301-620x.80b2.8032

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

Review 1.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

Review 2.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

3.  The influence of a suction device on fixation of a cemented cup using RSA.

Authors:  A John Timperley; Sarah L Whitehouse; Patrick G Hourigan
Journal:  Clin Orthop Relat Res       Date:  2008-11-08       Impact factor: 4.176

4.  Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.

Authors:  Nicholas D Clement; Martin Mitchell; Morag E Trayner; Daniel E Porter; Graham M Lawson; Richard Burnett
Journal:  Int Orthop       Date:  2013-08-22       Impact factor: 3.075

5.  Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.

Authors:  Håvard Bjerkholt; Oystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-09-02

6.  Revision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature.

Authors:  Guillem Figueras; Ramón Vives Planell; Ramón Serra Fernàndez; Joan Camí Biayna
Journal:  Open Orthop J       Date:  2016-10-31

7.  Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial.

Authors:  Einar Lindalen; Jon Dahl; Lars Nordsletten; Finnur Snorrason; Øystein Høvik; Stephan Röhrl
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.