Literature DB >> 9546231

Ex vivo human carotid artery bifurcation stenting: correlation of lesion characteristics with embolic potential.

T Ohki1, M L Marin, R T Lyon, G L Berdejo, K Soundararajan, M Ohki, J G Yuan, P L Faries, R A Wain, L A Sanchez, W D Suggs, F J Veith.   

Abstract

PURPOSE: To develop an ex vivo human carotid artery stenting model that can be used for the quantitative analysis of risk for embolization associated with balloon angioplasty and stenting and to correlate this risk with lesion characteristics to define lesions suitable for balloon angioplasty and stenting.
METHODS: Specimens of carotid plaque (n = 24) were obtained circumferentially intact from patients undergoing standard carotid endarterectomy. Carotid lesions were prospectively characterized on the basis of angiographic and duplex findings before endarterectomy and clinical findings. Specimens were encased in a polytetrafluoroethylene wrap and mounted in a flow chamber that allowed access for endovascular procedures and observations. Balloon angioplasty and stenting were performed under fluoroscopic guidance with either a Palmaz stent or a Wallstent endoprosthesis. Ex vivo angiograms were obtained before and after intervention. Effluent from each specimen was filtered for released embolic particles, which were microscopically examined, counted, and correlated with various plaque characteristics by means of multivariate analysis.
RESULTS: Balloon angioplasty and stenting produced embolic particles that consisted of atherosclerotic debris, organized thrombus, and calcified material. The number of embolic particles detected after balloon angioplasty and stenting was not related to preoperative symptoms, sex, plaque ulceration or calcification, or artery size. However, echolucent plaques generated a higher number of particles compared with echogenic plaques (p < 0.01). In addition, increased lesion stenosis also significantly correlated with the total number of particles produced by balloon angioplasty and stenting (r = 0.55). Multivariate analysis revealed that these two characteristics were independent risk factors.
CONCLUSIONS: Echolucent plaques and plaques with stenosis > or = 90% produced a higher number of embolic particles and therefore may be less suitable for balloon angioplasty and stenting. This ex vivo model can be used to identify high-risk lesions for balloon angioplasty and stenting and can aid in the evaluation of new devices being considered for carotid balloon angioplasty and stenting.

Entities:  

Mesh:

Year:  1998        PMID: 9546231     DOI: 10.1016/s0741-5214(98)70321-0

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  21 in total

Review 1.  Treatment of atherosclerotic disease at the cervical carotid bifurcation: current status and review of the literature.

Authors:  J J Connors; D Seidenwurm; J C Wojak; R W Hurst; M E Jensen; R Wallace; T Tomsick; J Barr; C Kerber; E Russell; G M Nesbit; A J Fox; F Y Tsai
Journal:  AJNR Am J Neuroradiol       Date:  2000-03       Impact factor: 3.825

Review 2.  New developments in endovascular interventions for extracranial carotid stenosis.

Authors:  W A Tan; C R Jarmolowski; L R Wechsler; M H Wholey
Journal:  Tex Heart Inst J       Date:  2000

3.  Carotid artery stenting: technical considerations.

Authors:  J J Vitek; G S Roubin; N Al-Mubarek; G New; S S Iyer
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

Review 4.  Cerebrovascular angioplasty and stenting for the prevention of stroke.

Authors:  J C Chaloupka; J B Weigele; S Mangla; W S Lesley
Journal:  Curr Neurol Neurosci Rep       Date:  2001-01       Impact factor: 5.081

5.  Diffusion-weighted MR imaging after angioplasty or angioplasty plus stenting of arteries supplying the brain.

Authors:  H J Jaeger; K D Mathias; R Drescher; E Hauth; G Bockisch; E Demirel; H M Gissler
Journal:  AJNR Am J Neuroradiol       Date:  2001-08       Impact factor: 3.825

Review 6.  [Proximal protection systems using carotid artery stent].

Authors:  I Q Grunwald; U Dorenbeck; C Axmann; C Roth; T Struffert; W Reith
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

Review 7.  [Distal protection devices in carotid stent].

Authors:  J Berkefeld; R du Mesnil de Rochemont; M Sitzer; F E Zanella
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

8.  Computerized Assessment of Carotid Plaque Echogenicity before Stenting.

Authors:  H Takahata; K Hayashi; N Kitagawa; M Kaminogo; H Koga; S Shibata
Journal:  Interv Neuroradiol       Date:  2002-01-10       Impact factor: 1.610

9.  Ultrasound-enhanced rt-PA thrombolysis in an ex vivo porcine carotid artery model.

Authors:  Kathryn E Hitchcock; Nikolas M Ivancevich; Kevin J Haworth; Danielle N Caudell Stamper; Deborah C Vela; Jonathan T Sutton; Gail J Pyne-Geithman; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2011-08       Impact factor: 2.998

10.  Characterization of carotid atherosclerosis and detection of soft plaque with use of black-blood MR imaging.

Authors:  K Yoshida; O Narumi; M Chin; K Inoue; T Tabuchi; K Oda; M Nagayama; N Egawa; M Hojo; Y Goto; Y Watanabe; S Yamagata
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-22       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.