Literature DB >> 21723448

Ultrasound-enhanced rt-PA thrombolysis in an ex vivo porcine carotid artery model.

Kathryn E Hitchcock1, Nikolas M Ivancevich, Kevin J Haworth, Danielle N Caudell Stamper, Deborah C Vela, Jonathan T Sutton, Gail J Pyne-Geithman, Christy K Holland.   

Abstract

Ultrasound is known to enhance recombinant tissue plasminogen activator (rt-PA) thrombolysis. In this study, occlusive porcine whole blood clots were placed in flowing plasma within living porcine carotid arteries. Ultrasonically induced stable cavitation was investigated as an adjuvant to rt-PA thrombolysis. Aged, retracted clots were exposed to plasma alone, plasma containing rt-PA (7.1 ± 3.8 μg/mL) or plasma with rt-PA and Definity® ultrasound contrast agent (0.79 ± 0.47 μL/mL) with and without 120-kHz continuous wave ultrasound at a peak-to-peak pressure amplitude of 0.44 MPa. An insonation scheme was formulated to promote and maximize stable cavitation activity by incorporating ultrasound quiescent periods that allowed for the inflow of Definity®-rich plasma. Cavitation was measured with a passive acoustic detector throughout thrombolytic treatment. Thrombolytic efficacy was measured by comparing clot mass before and after treatment. Average mass loss for clots exposed to rt-PA and Definity® without ultrasound (n = 7) was 34%, and with ultrasound (n = 6) was 83%, which constituted a significant difference (p < 0.0001). Without Definity® there was no thrombolytic enhancement by ultrasound exposure alone at this pressure amplitude (n = 5, p < 0.0001). In the low-oxygen environment of the ischemic artery, significant loss of endothelium occurred but no correlation was observed between arterial tissue damage and treatment type. Acoustic stable cavitation nucleated by an infusion of Definity® enhances rt-PA thrombolysis without apparent treatment-related damage in this ex vivo porcine carotid artery model.
Copyright © 2011. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21723448      PMCID: PMC4025997          DOI: 10.1016/j.ultrasmedbio.2011.05.011

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  56 in total

1.  Thrombolysis by ultrasound.

Authors:  G Trübestein; C Engel; F Etzel; A Sobbe; H Cremer; U Stumpff
Journal:  Clin Sci Mol Med Suppl       Date:  1976-12

2.  High-resolution computed tomography of the basilar artery: 1. Normal size and position.

Authors:  W R Smoker; M J Price; W D Keyes; J J Corbett; L R Gentry
Journal:  AJNR Am J Neuroradiol       Date:  1986 Jan-Feb       Impact factor: 3.825

3.  Microanatomy of the anterior cerebral artery.

Authors:  F B Gomes; M Dujovny; F Umansky; S K Berman; F G Diaz; J I Ausman; H G Mirchandani; W J Ray
Journal:  Surg Neurol       Date:  1986-08

4.  [Thrombolysis by ultrasound (author's transl)].

Authors:  A Sobbe; U Stumpff; G Trübestein; H Figge; W Kozuschek
Journal:  Klin Wochenschr       Date:  1974-12-01

5.  Spectral characteristics of acoustic cavitation.

Authors:  V I Ilyichev; V L Koretz; N P Melnikov
Journal:  Ultrasonics       Date:  1989-11       Impact factor: 2.890

6.  Enzymatic properties of the one- and two-chain form of tissue plasminogen activator.

Authors:  M Rånby; N Bergsdorf; T Nilsson
Journal:  Thromb Res       Date:  1982-07-15       Impact factor: 3.944

7.  The Thrombolysis in Myocardial Infarction (TIMI) trial. Phase I findings.

Authors: 
Journal:  N Engl J Med       Date:  1985-04-04       Impact factor: 91.245

8.  Hypoxia modulates the barrier and coagulant function of cultured bovine endothelium. Increased monolayer permeability and induction of procoagulant properties.

Authors:  S Ogawa; H Gerlach; C Esposito; A Pasagian-Macaulay; J Brett; D Stern
Journal:  J Clin Invest       Date:  1990-04       Impact factor: 14.808

9.  Functional coronary microvascular injury evident as increased permeability due to brief ischemia and reperfusion.

Authors:  I M Dauber; K M VanBenthuysen; I F McMurtry; G S Wheeler; E J Lesnefsky; L D Horwitz; J V Weil
Journal:  Circ Res       Date:  1990-04       Impact factor: 17.367

10.  Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak.

Authors:  I M Dauber; W T Pluss; A VanGrondelle; R S Trow; J V Weil
Journal:  J Appl Physiol (1985)       Date:  1985-08
View more
  48 in total

1.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

2.  Accuracy of a bistatic scattering substitution technique for calibration of focused receivers.

Authors:  Kyle T Rich; T Douglas Mast
Journal:  J Acoust Soc Am       Date:  2015-11       Impact factor: 1.840

3.  Efficacy of histotripsy combined with rt-PA in vitro.

Authors:  Kenneth B Bader; Kevin J Haworth; Himanshu Shekhar; Adam D Maxwell; Tao Peng; David D McPherson; Christy K Holland
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

4.  Histotripsy Thrombolysis on Retracted Clots.

Authors:  Xi Zhang; Gabe E Owens; Charles A Cain; Hitinder S Gurm; Jonathan Macoskey; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2016-05-07       Impact factor: 2.998

Review 5.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

6.  Spatial specificity and sensitivity of passive cavitation imaging for monitoring high-intensity focused ultrasound thermal ablation in ex vivo bovine liver.

Authors:  Kevin Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T D Mast
Journal:  Proc Meet Acoust       Date:  2013-06-02

7.  Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis.

Authors:  Aiwei Shi; Jonathan Lundt; Zilin Deng; Jonathan Macoskey; Hitinder Gurm; Gabe Owens; Xi Zhang; Timothy L Hall; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2018-09-30       Impact factor: 2.998

8.  Clot retraction affects the extent of ultrasound-enhanced thrombolysis in an ex vivo porcine thrombosis model.

Authors:  Jonathan T Sutton; Nikolas M Ivancevich; Stephen R Perrin; Deborah C Vela; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2013-03-01       Impact factor: 2.998

Review 9.  Ultrasound-mediated drug delivery for cardiovascular disease.

Authors:  Jonathan T Sutton; Kevin J Haworth; Gail Pyne-Geithman; Christy K Holland
Journal:  Expert Opin Drug Deliv       Date:  2013-03-01       Impact factor: 6.648

10.  Experimental validation of a finite-difference model for the prediction of transcranial ultrasound fields based on CT images.

Authors:  Guillaume Bouchoux; Kenneth B Bader; Joseph J Korfhagen; Jason L Raymond; Ravishankar Shivashankar; Todd A Abruzzo; Christy K Holland
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.