Literature DB >> 9536906

CT standard protocols are of limited value in assessing actual patient dose.

J P Wade1, J C Weyman, K E Goldstone.   

Abstract

In the last 10 years the use of computed tomography in radiodiagnosis has increased markedly and CT scanners are now present in most district general hospitals. Modern CT scanners are versatile in their operation and offer the operator a wide choice in exposure parameters which affect the doses received by the patients. As CT is a major contributor to medical radiation doses, the National Radiological Protection Board (NRPB) recommends that an estimate of typical patient dose should be made for commonly used local scanning protocols. A survey has been undertaken in the Anglia and Oxford region covering 12 CT scanners. Common procedures were chosen, concentrating on those most frequently carried out and giving higher effective doses. These included routine heads, routine chests, high resolution chests and abdomen/pelvis examinations. Questionnaires were sent out to each CT centre to collect data on standard protocols and to record the procedure used for five actual patients for each examination type thus enabling a comparison of the two methodologies. This study has shown that many examinations are tailored to the individual patient size and clinical indications, particularly in the chest/abdomen/pelvis. Thus, assessing doses based on collecting standard protocols may not give a true indication of the effective doses being received by particular patients.

Entities:  

Mesh:

Year:  1997        PMID: 9536906     DOI: 10.1259/bjr.70.839.9536906

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction.

Authors:  M Cohnen; H Fischer; J Hamacher; E Lins; R Kötter; U Mödder
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

2.  Chest Computed Tomographic Image Screening for Cystic Lung Diseases in Patients with Spontaneous Pneumothorax Is Cost Effective.

Authors:  Nishant Gupta; Dale Langenderfer; Francis X McCormack; Daniel P Schauer; Mark H Eckman
Journal:  Ann Am Thorac Soc       Date:  2017-01

3.  Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT.

Authors:  Sadi Gündoğdu; Kamran Mahmutyazicioğlu; Hüseyin Ozdemir; Ahmet Savranlar; Kiyasettin Asil
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

4.  Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations.

Authors:  Roshan S Livingstone; Paul M Dinakaran; Rekha S Cherian; Anu Eapen
Journal:  J Med Phys       Date:  2009-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.