A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI.

G J Barker1, A Simmons, S R Arridge, P S Tofts.   

Abstract

Inhomogeneity of the transmitted or received B1 field leads to intensity variations in MR images and spatial dependence in apparent concentration in MR spectra. We describe a simple method for investigating such variations. The transmitted B1 field can be measured both in vivo and in vitro which allows investigation of sample dependent effects that can not be measured on phantoms. For homogeneous regions the method also allows the received B1 field to be measured both in vivo and in vitro. Our method uses only a standard spin echo pulse sequence and simple region of interest analysis and should be implementable on any commercial scanner. The method is demonstrated using a variety of transmission and reception radiofrequency coils both in vivo and in vitro.

Mesh:

Year:  1998        PMID: 9534700     DOI: 10.1259/bjr.71.841.9534700

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  A simple method for mapping the B1 field distribution of linear RF coils.

Authors:  Jan Weis; Peter Andris; Ivan Frollo; Håkan Ahlström
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

Review 2.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

3.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

4.  Factors affecting the chemical exchange saturation transfer of Creatine as assessed by 11.7 T MRI.

Authors:  Shigeyoshi Saito; Yuki Mori; Nobuyoshi Tanki; Yoshichika Yoshioka; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2014-12-05

5.  Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout.

Authors:  Sohae Chung; Daniel Kim; Elodie Breton; Leon Axel
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

6.  Sources of variation in multi-centre brain MTR histogram studies: body-coil transmission eliminates inter-centre differences.

Authors:  P S Tofts; S C A Steens; M Cercignani; F Admiraal-Behloul; P A M Hofman; M J P van Osch; W M Teeuwisse; D J Tozer; J H T M van Waesberghe; R Yeung; G J Barker; M A van Buchem
Journal:  MAGMA       Date:  2006-09-07       Impact factor: 2.310

7.  MRI-based, wireless determination of the transfer function of a linear implant: Introduction of the transfer matrix.

Authors:  Janot P Tokaya; Alexander J E Raaijmakers; Peter R Luijten; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2018-04-24       Impact factor: 4.668

8.  MRI-based transfer function determination through the transfer matrix by jointly fitting the incident and scattered B 1 + field.

Authors:  Janot P Tokaya; Alexander J E Raaijmakers; Peter R Luijten; Alessandro Sbrizzi; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

9.  Intensity non-uniformity correction in MR imaging using residual cycle generative adversarial network.

Authors:  Xianjin Dai; Yang Lei; Yingzi Liu; Tonghe Wang; Lei Ren; Walter J Curran; Pretesh Patel; Tian Liu; Xiaofeng Yang
Journal:  Phys Med Biol       Date:  2020-11-27       Impact factor: 3.609

Review 10.  Recent progress and future challenges in MR electric properties tomography.

Authors:  Ulrich Katscher; Dong-Hyun Kim; Jin Keun Seo
Journal:  Comput Math Methods Med       Date:  2013-03-07       Impact factor: 2.238