Multiecho imaging with suboptimal spoiler gradients.

M D Does1, R E Snyder.   

Abstract

Although multiecho imaging may be used to measure transverse relaxation (T2), B1 and B0 inhomogeneity generally gives rise to unwanted coherence pathway signals which result in erroneous T2 measurements. One approach to suppressing this unwanted signal is to center each rf refocusing pulse between spoiler gradients which dephase the unwanted signal; however, hardware limitations often dictate the use of suboptimal spoiler gradients, that is, gradients that cannot provide sufficient dephasing strength. Using simulations, this work demonstrates that by means of a small additional spoiler gradient prior to the first rf refocusing pulse it is possible to reduce substantially the contribution from unwanted coherence pathways in multiecho imaging studies that use suboptimal spoiler gradients. This reduction of unwanted signal results in measured T2 values within approximately 1% of values obtained using spoiler gradients of optimal strength. These results were found for a wide range of biologically relevant T1 and T2 values, missettings of the rf refocusing pulse as large as 5%, and frequency offsets of up to 25 Hz. Multiecho image data agreed with the simulations. Using the additional spoiler gradient it is possible to reduce spoiler gradient strengths by up to 75%. Copyright 1998 Academic Press.

Entities:  

Mesh:

Year:  1998        PMID: 9533902     DOI: 10.1006/jmre.1997.1320

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  6 in total

1.  Compressed sensing CPMG with group-sparse reconstruction for myelin water imaging.

Authors:  Henry S Chen; Angshul Majumdar; Piotr Kozlowski
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

Review 2.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

3.  Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2017-04-20       Impact factor: 4.668

4.  T2 relaxometry with indirect echo compensation from highly undersampled data.

Authors:  Chuan Huang; Ali Bilgin; Tomoe Barr; Maria I Altbach
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

5.  On the inherent precision of mcDESPOT.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

6.  T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation.

Authors:  Tomoe Hagio; Chuan Huang; Aiden Abidov; Jaspreet Singh; Bujji Ainapurapu; Scott Squire; Denise Bruck; Maria I Altbach
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-25       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.