Literature DB >> 9531207

Emboli observed with use of transesophageal echocardiography immediately after tourniquet release during total knee arthroplasty with cement.

A T Berman1, J L Parmet, S P Harding, C L Israelite, K Chandrasekaran, J C Horrow, R Singer, H Rosenberg.   

Abstract

The right atrium and the right ventricle of fifty-five patients were imaged with transesophageal echocardiography during fifty-nine total knee arthroplasties performed with cement and the use of general anesthesia. The patients ranged in age from thirty-two to eighty-three years (mean, 65.5 years). Cardiopulmonary parameters were measured with use of hemodynamic monitoring systems, such as pulse oximeters, pulmonary artery catheters, and radial artery catheters. In addition, a femoral vein catheter was inserted on the side of the operation in ten of the fifty-five patients. Showers of echogenic material traversing the right atrium, the right ventricle, and the pulmonary artery after the tourniquet was deflated were observed to various degrees in all patients and lasted three to fifteen minutes. The mean peak intensity occurred within thirty seconds (range, twenty-four to forty-five seconds) after the tourniquet was released. The mean mixed venous oxygen saturation (and standard error of the mean) decreased (from 83+/-0.9 to 72+/-1.5 per cent) and the mean pulmonary arterial pressure increased (from 20+/-1.0 to 27+/-1.0 millimeters of mercury [2.67+/-0.13 to 3.60+/-0.13 kilopascals]), compared with the values before the tourniquet was released, in all patients. The pulmonary vascular resistance index increased after release of the tourniquet (to a maximum of 328+/-29 dyne.s.cm(-5).m2; p = 0.00002) only in the patients who had echogenic material that was at least 0.5 centimeter in diameter. Clinical pulmonary embolism developed postoperatively in three patients; all three had had echogenic particles that were more than 0.5 centimeter in maximum diameter on imaging. Blood aspirated from one of the pulmonary artery catheters and from five of the ten femoral vein catheters demonstrated fresh venous thrombus. Histological evaluation of the aspirates failed to demonstrate fat, marrow, or particles of polymethylmethacrylate. Surgeons should consider acute pulmonary embolism as a diagnosis when evaluating a patient who has hemodynamic collapse during total knee arthroplasty performed with cement.

Entities:  

Mesh:

Year:  1998        PMID: 9531207     DOI: 10.2106/00004623-199803000-00012

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  19 in total

1.  Orthopedic Surgery and Post-Operative Cognitive Decline in Idiopathic Parkinson's Disease: Considerations from a Pilot Study.

Authors:  Catherine C Price; Shellie-Anne Levy; Jared Tanner; Cyndi Garvan; Jade Ward; Farheen Akbar; Dawn Bowers; Mark Rice; Michael Okun
Journal:  J Parkinsons Dis       Date:  2015       Impact factor: 5.568

2.  The processing, mechanical properties and bioactivity of zinc based glass ionomer cements.

Authors:  D Boyd; M R Towler
Journal:  J Mater Sci Mater Med       Date:  2005-09       Impact factor: 3.896

3.  Pulmonary artery versus central venous catheter monitoring in the outcome of patients undergoing bilateral total knee replacement.

Authors:  Kethy M Jules-Elysee; Jacques T YaDeau; Michael K Urban
Journal:  HSS J       Date:  2008-11-11

4.  Reversible catastrophic fat embolism: a case report.

Authors:  Kethy Jules-Elysee; Thomas P Sculco
Journal:  HSS J       Date:  2006-02

5.  Less deep vein thrombosis due to transcutaneous fibular nerve stimulation in total knee arthroplasty: a randomized controlled trial.

Authors:  Masashi Izumi; Masahiko Ikeuchi; Koji Aso; Natsuki Sugimura; Yuko Kamimoto; Tetsuya Mitani; Tadashi Ueta; Takayuki Sato; Masataka Yokoyama; Tetsuro Sugiura; Toshikazu Tani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-24       Impact factor: 4.342

6.  Evaluation of echogenic emboli during total knee arthroplasty using transthoracic echocardiography.

Authors:  Peter Walker; Kamal Bali; Hans Van der Wall; Warwick Bruce
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-02-25       Impact factor: 4.342

7.  Markers of thrombin generation during resurfacing and noncemented total hip arthroplasty: a pilot study.

Authors:  Edwin P Su; Nikos Chatzoudis; Vasileios Sioros; George Go; Nigel E Sharrock
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  [Not Available].

Authors:  M R Sarkar; L Kinzl
Journal:  Oper Orthop Traumatol       Date:  1999-09       Impact factor: 1.154

9.  Navigation-assisted total knee arthroplasty in knees with osteoarthritis due to extra-articular deformity.

Authors:  Fabio Catani; Vitantonio Digennaro; Andrea Ensini; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-29       Impact factor: 4.342

10.  Higher early mortality with simultaneous rather than staged bilateral TKAs: results from the Swedish Knee Arthroplasty Register.

Authors:  Anna Stefánsdóttir; Lars Lidgren; Otto Robertsson
Journal:  Clin Orthop Relat Res       Date:  2008-08-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.