Literature DB >> 9526918

Hollow implants retrieved for fracture: a light and scanning electron microscope analysis of 4 cases.

A Piattelli1, A Scarano, M Piattelli, E Vaia, S Matarasso.   

Abstract

One of the possible complications of implant treatment is the occurrence of an implant fracture. Metal fatigue and biomechanical overload seem to be the most common causes of fractured implants. This study evaluated 4 implants (3 hollow cylinders and 1 hollow screw) which fractured after a mean loading period of 2.8 years. All implants had a 4 mm diameter and had been inserted in a posterior location. In 3 cases parafunctional habits were present. In all cases a vertical resorption of the peri-implant bone was present. The endosseous portion of the implant presented always a very high bone-implant contact percentage. Scanning electron microscopic examination showed that at least one of the implant holes was involved in the fracture line; no porosities or material defects were observed on the fractured surface of the implant. In hollow implants the holes could represent a site of less resistance.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9526918     DOI: 10.1902/jop.1998.69.2.185

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  6 in total

1.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

2.  Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue.

Authors:  María Prados-Privado; Sérgio A Gehrke; Rosa Rojo; Juan Carlos Prados-Frutos
Journal:  Med Biol Eng Comput       Date:  2018-06-11       Impact factor: 2.602

Review 3.  A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia.

Authors:  Reham B Osman; Michael V Swain
Journal:  Materials (Basel)       Date:  2015-03-05       Impact factor: 3.623

4.  SEM Analysis and Management of Fracture Dental Implant.

Authors:  Archana Singh; Ankita Singh; Rajul Vivek; T P Chaturvedi; Pankaj Chauhan; Shruti Gupta
Journal:  Case Rep Dent       Date:  2013-04-23

Review 5.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

Review 6.  Complications in implant dentistry.

Authors:  Ayesha Hanif; Saima Qureshi; Zeeshan Sheikh; Haroon Rashid
Journal:  Eur J Dent       Date:  2017 Jan-Mar
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.