Polarity and ion recombination correction factors for ionization chambers employed in electron beam dosimetry.

A Nisbet1, D I Thwaites.   

Abstract

Polarity and ion recombination correction factors for the NACP (type-02) design parallel-plate ionization chamber employed in a recent UK national electron beam dosimetry intercomparison are derived over the full range of energies and measurement conditions encountered. In addition, these effects have been studied for a further four NACP chambers, a Markus parallel-plate chamber, a Roos parallel-plate chamber and a NE2571 graphite walled cylindrical ionization chamber.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9509537     DOI: 10.1088/0031-9155/43/2/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Authors:  Catharine H Clark; Edwin G A Aird; Steve Bolton; Elizabeth A Miles; Andrew Nisbet; Julia A D Snaith; Russell A S Thomas; Karen Venables; David I Thwaites
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

2.  Pion effects in flattening filter-free radiation beams.

Authors:  Robert A Corns; Vicky W Huang; Steven D Thomas
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

3.  Ion recombination correction factors (P(ion)) for Varian TrueBeam high-dose-rate therapy beams.

Authors:  Stephen F Kry; Richard Popple; Andrea Molineu; David S Followill
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  Water equivalence of a solid phantom material for radiation dosimetry applications.

Authors:  Maegan A Gargett; Adam R Briggs; Jeremy T Booth
Journal:  Phys Imaging Radiat Oncol       Date:  2020-05-28

5.  Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration.

Authors:  Pablo Castro; Feliciano García-Vicente; Cristina Mínguez; Alejandro Floriano; David Sevillano; Leopoldo Pérez; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2008-01-22       Impact factor: 2.102

6.  Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams.

Authors:  Silvia Vargas Castrillón; Francisco Cutanda Henríquez
Journal:  J Med Phys       Date:  2017 Jul-Sep
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.