A quality assurance test tool for high dose-rate remote afterloading brachytherapy units.

Z Li1, T P Mitchell, J R Palta, C Liu.   

Abstract

A QA test tool is designed to quantitatively measure the HDR source positioning error, and to facilitate quick and dependable HDR timer linearity test and daily output constancy check. The test tool consists of two concentric disks. The lower disk has a cutout for inserting an HDR catheter, and the upper disk accepts a diode or miniature ionization chamber and can rotate relative to the lower disk. Ionization readings from the source (transferred to the center of the disks) are obtained at two rotational positions of the upper disk which houses the detector. The ratio of the readings is used to determine the source-positioning error of the HDR unit relative to the nominal source position by a simple triangulation principle. Experimental measurements confirm that the QA test tool is sensitive to approximately 0.2 mm variance in source positioning errors. In addition, the QA test tool is suitable for other common HDR QA tests such as the source travel step size test, the daily HDR unit output constancy check, and the timer linearity test. Its simple and robust design permits routine clinical use and provides a high confidence level in the accurate operation of HDR units.

Entities:  

Mesh:

Year:  1998        PMID: 9507484     DOI: 10.1118/1.598185

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Relative dosimetrical verification in high dose rate brachytherapy using two-dimensional detector array IMatriXX.

Authors:  A Manikandan; Sarkar Biplab; Perianayagam A David; R Holla; T R Vivek; N Sujatha
Journal:  J Med Phys       Date:  2011-07

2.  HDR and PDR 192Ir source activity control procedures, as the part of the quality assurance system at Brachytherapy Department of Greater Poland Cancer Centre.

Authors:  Grzegorz Zwierzchowski; Barbara Błasiak; Patrycja Stefaniak; Grzegorz Bielęda
Journal:  J Contemp Brachytherapy       Date:  2009-10-08

3.  Quality assurance procedures during commissioning of a treatment planning system as a tool to establish new standards before migration.

Authors:  Grzegorz Bielęda; Grzegorz Zwierzchowski; Barbara Błasiak; Janusz Skowronek
Journal:  J Contemp Brachytherapy       Date:  2010-07-06

4.  COMP report: CPQR technical quality control guidelines for brachytherapy remote afterloaders.

Authors:  Normand Frenière
Journal:  J Appl Clin Med Phys       Date:  2018-02-07       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.