Literature DB >> 9504962

Bone assessment after total knee arthroplasty by dual-energy X-ray absorptiometry: analysis protocol and reproducibility.

C Trevisan1, M Bigoni, M Denti, E C Marinoni, S Ortolani.   

Abstract

Bone quality is important for the success of joint prostheses implantation, and the assessment of bone density after total knee arthroplasty by means of dual-energy X-ray absorptiometry may be useful for monitoring implant stability. The aim of this study is to suggest a validated analysis protocol for the assessment of bone status after total knee arthroplasty. A dedicated densitometric analysis protocol of five regions of interest was designed, and 10 subjects who had received an uncemented knee prosthesis (8 females and 2 males, aged 55-74 years) underwent three consecutive scans in posteroanterior and lateral projections, with repositioning after each scan to test the suitability and reproducibility of the protocol. The reproducibility of the measurement of bone mineral content and density in the femoral and tibial regions ranged, respectively, from 2.1% to 4.1%, from 0.9% to 2.6% for the posteroanterior scans, and from 2.7% to 5.6% and from 2.3% to 4.7% for the lateral scans, depending on the considered region. Our results confirm that the suggested protocol allows precise assessment of bone mineral content and density, and that dual-energy X-ray absorptiometry is reliable for the evaluation of bone mass around prosthetic implants.

Mesh:

Substances:

Year:  1998        PMID: 9504962     DOI: 10.1007/s002239900444

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  7 in total

1.  Bone mineral density changes of the proximal tibia after revision total knee arthroplasty. A randomised study with the use of porous tantalum metaphyseal cones.

Authors:  Claus L Jensen; Michael M Petersen; Henrik M Schrøder; Bjarne Lund
Journal:  Int Orthop       Date:  2012-06-26       Impact factor: 3.075

2.  Influence of the tibial stem design on bone density after cemented total knee arthroplasty: a prospective seven-year follow-up study.

Authors:  Daniel Hernandez-Vaquero; Manuel A Garcia-Sandoval; Jose M Fernandez-Carreira; Richard Gava
Journal:  Int Orthop       Date:  2006-11-18       Impact factor: 3.075

Review 3.  [Absorptiometry].

Authors:  S Prevrhal
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

4.  Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients.

Authors:  Hans-Peter W van Jonbergen; Kenneth Koster; Luc Labey; Bernardo Innocenti; Albert van Kampen
Journal:  BMC Musculoskelet Disord       Date:  2010-04-20       Impact factor: 2.362

5.  Knee flexion influences periprosthetic BMD measurement in the tibia. Suggestions for a reproducible clinical scan protocol.

Authors:  Maiken Stilling; Kjeld Søballe; Kristian Larsen; Niels Trolle Andersen; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

6.  Variable bone mineral density reductions post-unicompartmental knee arthroplasty.

Authors:  Mahmut Tuncer; Rajesh Patel; Justin P Cobb; Ulrich N Hansen; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-27       Impact factor: 4.342

7.  Periprosthetic tibial bone mineral density changes after total knee arthroplasty.

Authors:  Antti Jaroma; Tarja Soininvaara; Heikki Kröger
Journal:  Acta Orthop       Date:  2016-04-27       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.