Literature DB >> 9502631

Assessment of diagnostic performance of quantitative flow measurements in normal subjects and patients with angiographically documented coronary artery disease by means of nitrogen-13 ammonia and positron emission tomography.

O Muzik1, C Duvernoy, R S Beanlands, S Sawada, F Dayanikli, E R Wolfe, M Schwaiger.   

Abstract

OBJECTIVES: Regional myocardial blood flow (MBF) and flow reserve measurements using nitrogen-13 (N-13) ammonia positron emission tomography (PET) were compared with quantitative coronary angiography to determine their utility in the detection of significant coronary artery disease (CAD).
BACKGROUND: Dynamic PET protocols using N-13 ammonia allow regional quantification of MBF and flow reserve. To establish the diagnostic performance of this method, the sensitivity and specificity must be known for varying decision thresholds.
METHODS: MBF and flow reserve for three coronary territories were determined in 20 normal subjects and 31 patients with angiographically documented CAD by means of dynamic PET and a three-compartment model for N-13 ammonia kinetics. Ten normal subjects defined the normal mean and SD of MBF and flow reserve, and 10 normal subjects were compared with patients. PET flow obtained in the territory with the most severe stenosis in each patient was correlated with the angiographic assessment of the stenosis (severity > or = 50%, > or = 70%, > or = 90%). Receiver operating characteristic (ROC) curve analysis was performed for 1.5, 2.0, 2.5, 3.0 and 4.0 SD of flow abnormalities.
RESULTS: MBF and flow reserve values from the normal subjects and from territories with documented stenoses > or = 50% were significantly different (p < 0.05). A significant difference was found between normal subjects and angiographically normal territories of patients with CAD. High diagnostic accuracy and sensitivity, with moderately high specificity, were demonstrated for detection of all stenoses.
CONCLUSIONS: Quantification of myocardial perfusion using dynamic PET and N-13 ammonia provides a high performance level for the detection and localization of CAD. The specificity of dynamic PET was excellent in patients with a low likelihood of CAD, whereas an abnormal flow reserve in angiographically normal territories was postulated to represent early functional abnormalities of vascular reactivity.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9502631     DOI: 10.1016/s0735-1097(97)00526-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  35 in total

1.  Clinical cardiac PET in the future.

Authors:  Juhani Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-17       Impact factor: 9.236

Review 2.  PET: Is myocardial flow quantification a clinical reality?

Authors:  Antti Saraste; Sami Kajander; Chunlei Han; Sergey V Nesterov; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

Review 3.  Left main coronary artery disease: A review of the spectrum of noninvasive diagnostic modalities.

Authors:  Nishtha Sareen; Karthik Ananthasubramaniam
Journal:  J Nucl Cardiol       Date:  2015-10-20       Impact factor: 5.952

Review 4.  Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Authors:  Roberto Sciagrà; Alessandro Passeri; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Alessia Gimelli; Fabien Hyafil; Denis Agostini; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-02-05       Impact factor: 9.236

5.  Simplified quantification of PET myocardial blood flow: The need for technical standardization.

Authors:  Jonathan B Moody; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2018-11-05       Impact factor: 5.952

Review 6.  Myocardial perfusion imaging by cardiac magnetic resonance.

Authors:  Juerg Schwitter
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

7.  Should we use more PET-CT in clinical cardiology?

Authors:  J Knuuti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-05       Impact factor: 9.236

8.  Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment.

Authors:  Federico E Mordini; Tariq Haddad; Li-Yueh Hsu; Peter Kellman; Tracy B Lowrey; Anthony H Aletras; W Patricia Bandettini; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2014-01

9.  Cine CT for attenuation correction in cardiac PET/CT.

Authors:  Adam M Alessio; Steve Kohlmyer; Kelley Branch; Grace Chen; James Caldwell; Paul Kinahan
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

10.  Myocardial blood volume is associated with myocardial oxygen consumption: an experimental study with cardiac magnetic resonance in a canine model.

Authors:  Kyle S McCommis; Haosen Zhang; Thomas A Goldstein; Bernd Misselwitz; Dana R Abendschein; Robert J Gropler; Jie Zheng
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.