Development of high magnetic field MRI techniques is hampered by the significant artifacts produced by B0 field inhomogeneities in the excited slices. A technique, gradient-echo slice excitation profile imaging (GESEPI), is presented for recovering the signal lost caused by intravoxel phase dispersion in T2*-weighted images. This technique superimposes an incremental gradient offset on the slice refocusing gradient to sample k-space over the full range of spatial frequencies of the excitation profile. A third Fourier transform of the initial two-dimensional image set generates an image set in which the artifacts produced by the low-order B0 inhomogeneity field gradients in the sample are separated and removed from the high-order microscopic field gradients responsible for T2* contrast. Application to high field brain imaging, at 3.0 T for human and at 9.4 T for immature rat imaging demonstrates the significant improvement in quality of the T2*-weighted contrast images.

Entities:  

Mesh:

Year:  1998        PMID: 9498596     DOI: 10.1002/mrm.1910390310

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

3.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  Variable-density spiral 3D tailored RF pulses.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  MR imaging to assess immediate response to irreversible electroporation for targeted ablation of liver tissues: preclinical feasibility studies in a rodent model.

Authors:  Yue Zhang; Yang Guo; Ann B Ragin; Robert J Lewandowski; Guang-Yu Yang; Grace M Nijm; Alan V Sahakian; Reed A Omary; Andrew C Larson
Journal:  Radiology       Date:  2010-08       Impact factor: 11.105

6.  Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses.

Authors:  V Andrew Stenger; Marius S Giurgi; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

7.  An efficient automated z-shim based method to correct through-slice signal loss in EPI at 3T.

Authors:  Helen Marshall; Joseph V Hajnal; Jane E Warren; Richard J Wise; David J Larkman
Journal:  MAGMA       Date:  2009-02-24       Impact factor: 2.310

8.  Simultaneous z-shim method for reducing susceptibility artifacts with multiple transmitters.

Authors:  Weiran Deng; Cungeng Yang; Vijayanand Alagappan; Lawrence L Wald; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

Review 9.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

10.  Decreased leftward 'aiming' motor-intentional spatial cuing in traumatic brain injury.

Authors:  Daymond Wagner; Paul J Eslinger; A M Barrett
Journal:  Neuropsychology       Date:  2016-09       Impact factor: 3.295

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.