Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.

T Kurita1, K Morita, S Kato, M Kikura, M Horie, K Ikeda.   

Abstract

A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of both with cardiac output determined by electromagnetic flowmetry (EMCO) under controlled laboratory conditions in 10 swine. They were monitored with a pulmonary artery catheter, femoral artery catheter and electromagnetic flowmeter placed around the ascending aorta. LiDCO, ThDCO and EMCO measurements were determined at baseline, in a hyperdynamic state produced by administration of dobutamine, at a second baseline and finally in a hypodynamic state induced by propranolol during deep anaesthesia. Data were analysed by linear regression analysis and the comparison method described by Bland and Altman; bias and precision of both LiDCO and ThDCO compared with EMCO were calculated by the method of Sheiner and Beal. The correlation coefficient between LiDCO and EMCO (0.95) was higher than that between ThDCO and EMCO (0.87). The precision value of LiDCO (0.04) was significantly less (i.e. better) than that of ThDCO (0.09). The results of this study indicated that LiDCO was more reliable compared with conventional ThDCO.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9496211     DOI: 10.1093/bja/79.6.770

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  13 in total

1.  Applications of minimally invasive cardiac output monitors.

Authors:  Jahan Porhomayon; Gino Zadeii; Samuel Congello; Nader D Nader
Journal:  Int J Emerg Med       Date:  2012-04-24

Review 2.  A definition of normovolaemia and consequences for cardiovascular control during orthostatic and environmental stress.

Authors:  Jasper Truijen; Morten Bundgaard-Nielsen; Johannes J van Lieshout
Journal:  Eur J Appl Physiol       Date:  2010-01-07       Impact factor: 3.078

3.  A comparison of lithium dilution cardiac output measurements made using central and antecubital venous injection of lithium chloride.

Authors:  M M Jonas; F E Kelly; R A Linton; D M Band; T K O'Brien; N W Linton
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

4.  Comparison of a central and a peripheral (cephalic vein) injection site for the measurement of cardiac output using the lithium-dilution cardiac output technique in anesthetized dogs.

Authors:  Douglas J Mason; Michael O'Grady; J Paul Woods; Wayne McDonell
Journal:  Can J Vet Res       Date:  2002-07       Impact factor: 1.310

5.  Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique.

Authors:  Maria Gabriella Costa; Giorgio Della Rocca; Paolo Chiarandini; Silvia Mattelig; Livia Pompei; Mauricio Sainz Barriga; Toby Reynolds; Maurizio Cecconi; Paolo Pietropaoli
Journal:  Intensive Care Med       Date:  2007-10-06       Impact factor: 17.440

6.  Lithium dilution cardiac output measurements using a peripheral injection site comparison with central injection technique and thermodilution.

Authors:  T Kurita; K Morita; S Kato; H Kawasaki; M Kikura; T Kazama; K Ikeda
Journal:  J Clin Monit Comput       Date:  1999-07       Impact factor: 2.502

7.  Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery.

Authors:  Per K Eide
Journal:  Fluids Barriers CNS       Date:  2011-02-04

Review 8.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

9.  A Prospective Study to Evaluate the Accuracy of Pulse Power Analysis to Monitor Cardiac Output in Critically Ill Patients.

Authors:  Maurizio Cecconi; Jayne Fawcett; R Michael Grounds; Andrew Rhodes
Journal:  BMC Anesthesiol       Date:  2008-02-18       Impact factor: 2.217

Review 10.  Equipment review: an appraisal of the LiDCO plus method of measuring cardiac output.

Authors:  Rupert M Pearse; Kashif Ikram; John Barry
Journal:  Crit Care       Date:  2004-05-05       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.