The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea.

A I Brain1, C Verghese, E V Addy, A Kapila, J Brimacombe.   

Abstract

We have assessed the efficacy of a new laryngeal mask prototype, the intubating laryngeal mask airway (ILMA), as a ventilatory device and blind intubation guide. The ILMA consists of an anatomically curved, short, wide bore, stainless steel tube sheathed in silicone which is bonded to a laryngeal mask and a guiding handle. It has a single moveable aperture bar, a guiding ramp and can accommodate an 8 mm tracheal tube (TT). After induction of anaesthesia with propofol 2.5 mg kg-1 and fentanyl 2.5 micrograms kg-1, the device was inserted successfully at the first attempt in all 150 (100%) patients and adequate ventilation achieved in all, with minor adjustments required in four patients. Placement did not require movement of the head and neck or insertion of the fingers in the patient's mouth. Blind tracheal intubation using a straight silicone cuffed TT was attempted after administration of atracurium 0.5 mg kg-1. If resistance was felt during intubation, a sequence of adjusting manoeuvres was used based on the depth at which resistance occurred. Tracheal intubation was possible in 149 of 150 (99.3%) patients. In 75 (50%) patients no resistance was encountered and the trachea was intubated at the first attempt, 28 (19%) patients required one adjusting manoeuvre and 46 (31%) patients required 2-4 adjusting manoeuvres before intubation was successful. There were 13 patients with potential or known airway problems. The lungs of all of these patients were ventilated easily and the trachea intubated using the ILMA. In 10 of 13 (77%) of these patients, no resistance was encountered and the trachea was intubated at the first attempt; three of 13 (23%) patients required one adjusting manoeuvre. Tracheal intubation required significantly fewer adjusting manoeuvres in patients with a predicted or known difficult airway (P < 0.05). We conclude that the ILMA appeared on initial assessment to be an effective ventilatory device and intubation guide for routine and difficult airway patients not at risk of gastric aspiration.

Entities:  

Mesh:

Year:  1997        PMID: 9496199     DOI: 10.1093/bja/79.6.704

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  26 in total

Review 1.  The laryngeal mask airway: potential applications in neonates.

Authors:  D Trevisanuto; M Micaglio; P Ferrarese; V Zanardo
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2004-11       Impact factor: 5.747

2.  The intubating laryngeal mask: is there a role for paramedics?

Authors:  Robert Menzies; Hamid Manji
Journal:  Emerg Med J       Date:  2007-03       Impact factor: 2.740

3.  Evaluation of the Effect of Tracheal Tube Orientation on Success of Intubation through Intubating Laryngeal Mask Airway.

Authors:  Swati Chhatrapati; Anjana Sahu; Subhhash Sadashiv Auti; Swapnil Ganesh Aswar
Journal:  J Clin Diagn Res       Date:  2016-05-01

4.  Evaluation of Fastrach Laryngeal Mask Airway as an Alternative to Fiberoptic Bronchoscope to Manage Difficult Airway: A Comparative Study.

Authors:  Radhey Shyam; Ajay Kumar Chaudhary; Pushplata Sachan; Prithvi Kumar Singh; Gyan Prakash Singh; Vinod Kumar Bhatia; Girish Chandra; Dinesh Singh
Journal:  J Clin Diagn Res       Date:  2017-01-01

5.  Difficult intubation using intubating laryngeal mask airway in conjunction with a fiber optic bronchoscope.

Authors:  Jin-Sun Kim; Dong-Kyun Seo; Chang-Joon Lee; Hwa-Sung Jung; Seong-Su Kim
Journal:  J Dent Anesth Pain Med       Date:  2015-09-30

6.  Fiberoptic-guided tracheal tube placement through the air-Q® Intubating Laryngeal Airway: a performance study in a manikin.

Authors:  Richard E Galgon; Kristopher M Schroeder; Christopher S Schmidt; Adrian A Matioc; Seungbong Han; Adin-Cristian Andrei; Aaron M Joffe
Journal:  J Anesth       Date:  2011-07-29       Impact factor: 2.078

7.  Laryngeal Mask Airway for neonatal resuscitation in a developing country: evaluation of an educational intervention. Neonatal LMA: an educational intervention in DRC.

Authors:  Vincenzo Zanardo; Alphonse Simbi; Massimo Micaglio; Francesco Cavallin; Leon Tshilolo; Daniele Trevisanuto
Journal:  BMC Health Serv Res       Date:  2010-08-31       Impact factor: 2.655

8.  [LMA CTrach: initial experiences in patients with difficult-to-manage airways].

Authors:  A Timmermann; S Russo; U Natge; J Heuer; B M Graf
Journal:  Anaesthesist       Date:  2006-05       Impact factor: 1.041

9.  Tri-colour concept with the use of LMA CTrach.

Authors:  Geetanjali Chilkoti; Medha Mohta
Journal:  Indian J Anaesth       Date:  2011-03

10.  Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach™): A randomized study of LMA- Fastrach™ wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube.

Authors:  Megha U Sharma; Satinder Gombar; Kanti K Gombar; Baljit Singh; Nidhi Bhatia
Journal:  Indian J Anaesth       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.