Fiberoptic-guided tracheal tube placement through the air-Q® Intubating Laryngeal Airway: a performance study in a manikin.

Richard E Galgon1, Kristopher M Schroeder, Christopher S Schmidt, Adrian A Matioc, Seungbong Han, Adin-Cristian Andrei, Aaron M Joffe.   

Abstract

PURPOSE: This study characterizes the performance and success rate for fiberoptic-guided tracheal tube placement through the air-Q(®) Intubating Laryngeal Airway (air-Q).
METHODS: Using a manikin, anesthesia trainees and staff anesthesiologists, experienced in fiberoptic-guided intubation, performed five consecutive fiberoptic-guided tracheal tube placements via the air-Q. Participant characteristics, procedure segment times, total procedure times, and observed failures were recorded. Linear mixed effect models with random slopes and intercepts were used to assess participant performance.
RESULTS: Ten anesthesia trainees and ten staff anesthesiologists participated. Anesthesia trainees were younger and had practiced for fewer years compared to staff anesthesiologists. Gender was equally distributed between the groups. Both segmental and overall procedure times decreased from the first to the fifth trial among all participants, independent of experience level and gender. Overall mean procedure time decreased from 102 ± 31 to 68 ± 14 s, representing a relative time reduction of 33% and a mean time difference of 34 s [95% confidence interval (CI) 22-47 s; p < 0.0001]. Tracheal tube placement was successful in all attempts; however, three tracheal tube dislodgements occurred during air-Q removal (overall procedure success 97%).
CONCLUSIONS: Fiberoptic-guided tracheal tube placement through the air-Q can be performed in a clinically acceptable period of time with high success by operators skilled in fiberoptic-guided intubation. Tracheal tube dislodgement during air-Q removal remains a potential risk that should be emphasized.

Entities:  

Mesh:

Year:  2011        PMID: 21796508     DOI: 10.1007/s00540-011-1205-5

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  15 in total

1.  Difficult Airway Society guidelines for management of the unanticipated difficult intubation.

Authors:  J J Henderson; M T Popat; I P Latto; A C Pearce
Journal:  Anaesthesia       Date:  2004-07       Impact factor: 6.955

2.  The airQ, old or new?

Authors:  A M Joffe; R E Galgon; E C Chiew
Journal:  Anaesth Intensive Care       Date:  2010-09       Impact factor: 1.669

3.  Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

Authors:  K M Jackson; T M Cook
Journal:  Anaesthesia       Date:  2007-04       Impact factor: 6.955

4.  Fibreoptic intubation using three airway conduits in a manikin: the effect of operator experience.

Authors:  I Hodzovic; J Petterson; A R Wilkes; I P Latto
Journal:  Anaesthesia       Date:  2007-06       Impact factor: 6.955

5.  Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™.

Authors:  Y M Karim; D E Swanson
Journal:  Anaesthesia       Date:  2011-03       Impact factor: 6.955

6.  The intubating laryngeal mask. I: Development of a new device for intubation of the trachea.

Authors:  A I Brain; C Verghese; E V Addy; A Kapila
Journal:  Br J Anaesth       Date:  1997-12       Impact factor: 9.166

7.  The distance between the grille of the laryngeal mask airway and the vocal cords. Is conventional intubation through the laryngeal mask safe?

Authors:  T Asai; I P Latto; R S Vaughan
Journal:  Anaesthesia       Date:  1993-08       Impact factor: 6.955

8.  The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea.

Authors:  A I Brain; C Verghese; E V Addy; A Kapila; J Brimacombe
Journal:  Br J Anaesth       Date:  1997-12       Impact factor: 9.166

9.  Repeated attempts improve tracheal tube insertion time using the intubating laryngeal airway in a mannequin.

Authors:  David T Wong; Narisa Apichatibutra; Gagan Arora; Jacqueline A Woo; Victor Y Lee; Lakshmi Venkat Raghavan
Journal:  J Clin Anesth       Date:  2010-12       Impact factor: 9.452

10.  Evaluation of four airway training manikins as patient simulators for the insertion of single use laryngeal mask airways.

Authors:  T M Cook; C Green; J McGrath; R Srivastava
Journal:  Anaesthesia       Date:  2007-07       Impact factor: 6.955

View more
  3 in total

1.  Evaluation of chest compression effect on airway management with air-Q, aura-i, i-gel, and Fastrack intubating supraglottic devices by novice physicians: a randomized crossover simulation study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Yoshiroh Kaminoh; Shin-Ichi Nishi
Journal:  J Anesth       Date:  2014-02-22       Impact factor: 2.078

2.  Comparison of learning performance of 2 intubating laryngeal mask airways in novice: A randomized crossover manikin study.

Authors:  Zi-Jia Liu; Jie Yi; Wei-Yun Chen; Xiu-Hua Zhang; Yu-Guang Huang
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

3.  Combined Video Laryngoscope and Fiberoptic Nasal Intubation.

Authors:  Stacey M Nedrud; Douglas G Baasch; John D Cabral; Daniel S McEwen; Jayanth Dasika
Journal:  Cureus       Date:  2021-11-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.