Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection.

M P Federle1, P J Chang, S Confer, B Ozgun.   

Abstract

PURPOSE: To determine the frequency and clinical effects of extravasation related to rapid bolus infusion of ionic and nonionic contrast media.
MATERIALS AND METHODS: Records of 5,106 computed tomographic studies in adult patients who underwent mechanical bolus injection of contrast medium through a plastic cannula in an upper extremity were retrospectively reviewed.
RESULTS: Mean infusion rate was 2.8 mL/sec (range, 1-5 mL/sec). Extravasation occurred in 48 (0.9%) patients, including in four of 928 patients who received the median injection rate (2.5 mL/sec). Injection rate was not correlated with frequency or amount of extravasation. Average age and use of ionic versus nonionic contrast medium were identical in patients with and in those without extravasation. There was no sex difference. Thirty-one patients had extravasation of ionic contrast medium; nine of these had extravasation of at least 50 mL. Seventeen patients had extravasation of nonionic contrast medium; seven of these had extravasation of at least 50 mL. Hyaluronidase infiltration was often used as treatment for larger extravasations (in 10 patients each with extravasation of ionic or nonionic medium). No patient required surgical intervention, and none had severe or permanent long-term effects.
CONCLUSION: The frequency of extravasation of contrast medium after mechanical bolus injection is higher than that reported for hand-injection or drip-infusion techniques, but there is no correlation between injection rate and extravasation frequency.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9494479     DOI: 10.1148/radiology.206.3.9494479

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

Review 1.  MDCT of primary liver malignancies.

Authors:  Alfonso Marchianò
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

2.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

3.  Incidence of intravenous contrast extravasation: increased risk for patients with deep brachial catheter placement from the emergency department.

Authors:  Andrew D Hardie; Borko Kereshi
Journal:  Emerg Radiol       Date:  2014-01-07

4.  [Acute compartment syndrome of the forearm after paravasation of contrast medium. Case report].

Authors:  F Ensat; M Babl; M Spies
Journal:  Radiologe       Date:  2010-03       Impact factor: 0.635

5.  MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates.

Authors:  S Keil; C Plumhans; F F Behrendt; M Das; S Stanzel; G Mühlenbruch; P Seidensticker; C Knackstedt; A H Mahnken; R W Günther; J E Wildberger
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

6.  Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT.

Authors:  Florian F Behrendt; Hubertus Pietsch; Gregor Jost; Martin A Sieber; Sebastian Keil; Cedric Plumhans; Peter Seidensticker; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2010-02-24       Impact factor: 5.315

7.  Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans.

Authors:  Eui Jin Hwang; Cheong-Il Shin; Young Hun Choi; Chang Min Park
Journal:  Eur Radiol       Date:  2018-06-06       Impact factor: 5.315

8.  Extrinsic warming of low-osmolality iodinated contrast media to 37°C reduced the rate of allergic-like reaction.

Authors:  Bin Zhang; Jing Liu; Yuhao Dong; Baoliang Guo; Zhouyang Lian; Hui Yu; Xiaoning Luo; Xiaokai Mo; Lu Zhang; Wenhui Huang; Fusheng Ouyang; Xinyun Li; Changhong Liang; Shuixing Zhang
Journal:  Allergy Asthma Proc       Date:  2018-11-01       Impact factor: 2.587

9.  [Development of compartment syndrome after intravenous administration of an X-ray contrast medium. Recommendations on acute therapy regimens].

Authors:  N Hawi; M Citak; E Liodakis; M Petri; C Haasper; C Krettek; R Meller
Journal:  Unfallchirurg       Date:  2014-04       Impact factor: 1.000

10.  ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group.

Authors:  Masahiro Jinzaki; Kakuya Kitagawa; I-Chen Tsai; Carmen Chan; Wei Yu; Hwan Seok Yong; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-08       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.