Literature DB >> 29876706

Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans.

Eui Jin Hwang1, Cheong-Il Shin1, Young Hun Choi1, Chang Min Park2,3.   

Abstract

OBJECTIVE: To evaluate the frequency, outcome, and risk factors of intravenous contrast media (CM) extravasation during contrast-enhanced CT scans in a large population.
METHODS: After institutional review board approval, 142,651 patients (72,976 males and 69,675 females; mean age, 59.9 ± 13.0 years) who underwent contrast-enhanced CT scans with intravenous CM between January 2015 and April 2017 were retrospectively included. The frequency of CM extravasations and their clinical outcomes were investigated. Risk factors of CM extravasation were evaluated using logistic regression with generalized estimating equation analyses. In addition, the frequency and risk factors of large-volume (≥100 ml) CM extravasation were also investigated.
RESULTS: CM extravasation occurred in 0.23% (321/142,651) of patients, all of which were of mild degree and resolved without any sequelae through conservative management. Multivariate analysis revealed that female gender [odds ratio (OR) = 1.61; p < 0.001], 60 < age ≤ 70 years (OR = 1.71; p = 0.004) or age > 70 years (OR = 2.49; p < 0.001), patients in general wards (OR = 2.71; p < 0.001) or ICUs (OR = 4.76; p < 0.001), 9.4 < CM viscosity ≤ 10.0 (OR = 1.65; p = 0.015), 10.0 < CM viscosity ≤ 10.6 (OR = 1.60; p = 0.002), and CM viscosity > 16.0 (OR = 2.55, p < 0.001) were independent risk factors for CM extravasation.
CONCLUSION: CM extravasation during contrast-enhanced CT scans was uncommon with no substantial clinical consequences. Several risk factors that may have the potential to reduce the occurrence of CM extravasation were identified. KEY POINTS: • The observed frequency of contrast media extravasation during contrast-enhanced CT scans was 0.23% (321/142,651). • Significant risk factors for contrast media extravasation were female gender, age older than 60 years, patients in general wards or ICUs, and the viscosity of contrast media greater than 9.4 mPa∙s. • The main preventive action for contrast media extravasation would be to lower the viscosity of contrast media.

Entities:  

Keywords:  Contrast media; Extravasation of diagnostic and therapeutic materials; Injection site reaction; Tomography, X-ray computed

Mesh:

Substances:

Year:  2018        PMID: 29876706     DOI: 10.1007/s00330-018-5507-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

1.  Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study.

Authors:  S A Schwab; M Uder; K Anders; M C Heinrich; M A Kuefner
Journal:  Rofo       Date:  2009-03-11

2.  Safe use of an intravenous power injector for CT: experience and protocol.

Authors:  S G Miles; J F Rasmussen; T Litwiller; A Osik
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

3.  Intravenous contrast extravasation during CT: a national data registry and practice quality improvement initiative.

Authors:  Thomas M Dykes; Mythreyi Bhargavan-Chatfield; Raymond B Dyer
Journal:  J Am Coll Radiol       Date:  2014-09-22       Impact factor: 5.532

4.  Extravasation injury with nonionic contrast material.

Authors:  M Memolo; R Dyer; R J Zagoria
Journal:  AJR Am J Roentgenol       Date:  1993-01       Impact factor: 3.959

5.  Local reactions after injection of iodinated contrast material: detection, management, and outcome.

Authors:  R H Cohan; M A Bullard; J H Ellis; S C Jan; I R Francis; W L Garner; N R Dunnick
Journal:  Acad Radiol       Date:  1997-11       Impact factor: 3.173

Review 6.  Contrast medium extravasation injury: guidelines for prevention and management.

Authors:  Marie-France Bellin; Jarl A Jakobsen; Isabelle Tomassin; Henrik S Thomsen; Sameh K Morcos; H S Thomsen; S K Morcos; T Almén; P Aspelin; M F Bellin; W Clauss; H Flaten; N Grenier; J-M Ideé; J A Jakobsen; G P Krestin; F Stacul; J A W Webb
Journal:  Eur Radiol       Date:  2002-09-06       Impact factor: 5.315

7.  Lessons learned from 118,970 multidetector computed tomographic intravenous contrast material administrations: impact of catheter dwell time and gauge, catheter location, rate of contrast material administration, and patient age and sex on volume of extravasate.

Authors:  Courtney Coursey Moreno; Daniella Pinho; Rendon C Nelson; Dushyant V Sahani; Melissa Jenkins; MaryAnne Zabrycki; Humaira Chaudhry; Jian Kang; Zhengjia Chen
Journal:  J Comput Assist Tomogr       Date:  2013 Mar-Apr       Impact factor: 1.826

Review 8.  Management of large volume CT contrast medium extravasation injury: technical refinement and literature review.

Authors:  Mark V Schaverien; Demetrius Evison; Stephen J McCulley
Journal:  J Plast Reconstr Aesthet Surg       Date:  2007-04-25       Impact factor: 2.740

9.  Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections.

Authors:  Carolyn L Wang; Richard H Cohan; James H Ellis; Saroja Adusumilli; N Reed Dunnick
Journal:  Radiology       Date:  2007-04       Impact factor: 11.105

10.  Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases.

Authors:  C L Sistrom; S B Gay; L Peffley
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

View more
  3 in total

1.  Drug Extravasation in a Large General Hospital in Hunan, China: A Retrospective Survey.

Authors:  Zhihong Gong; Jinghui Zhang; Jianmei Hou; Shujie Chen; Zixin Hu; Xiaoya Kong; Guiyuan Ma; Lingxia Luo
Journal:  Risk Manag Healthc Policy       Date:  2021-12-11

2.  Intravenous contrast medium extravasation: systematic review and updated ESUR Contrast Media Safety Committee Guidelines.

Authors:  Giles Roditi; Nadir Khan; Aart J van der Molen; Marie-France Bellin; Michele Bertolotto; Torkel Brismar; Jean-Michel Correas; Ilona A Dekkers; Remy W F Geenen; Gertraud Heinz-Peer; Andreas H Mahnken; Carlo C Quattrocchi; Alexander Radbruch; Peter Reimer; Laura Romanini; Fulvio Stacul; Henrik S Thomsen; Olivier Clément
Journal:  Eur Radiol       Date:  2022-02-17       Impact factor: 7.034

3.  Hand compartment syndrome secondary to contrast media extravasation: A case report.

Authors:  Badara Diop; Guillaume Tcheutchoua Soh; Armel Franck Tene Nde; Ndiamé Sarr; Abdou Yacine Ndoye; Jean Claude Sane
Journal:  Int J Surg Case Rep       Date:  2022-09-02
  3 in total