Literature DB >> 9493720

Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique.

M Takahashi1, W M Maguire, M Ashtari, A Khan, Z Papp, R Alberico, W Campbell, T Eacobacci, P G Herman.   

Abstract

RATIONALE AND
OBJECTIVES: This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum.
METHODS: Phantom studies were conducted to evaluate resolution and noise level, then a patient study was then done. Fifty consecutive patients (10 normal and 40 abnormal) cases were examined. After a scan (250 mAs, 120OkVp) of the entire thorax, five additional slices (50 mAs, 120kVp) at the level of the abnormality were obtained. Three independent observers evaluated the visibility of normal lung and mediastinal structures, as well as image noise. The mean score was compared between the standard and low doses. In a second study, an independent evaluation of the presence or absence of pathologic findings was made by four observers.
RESULTS: Lucite phantom studies demonstrated diminished low-contrast resolution and increased noise level for the low-dose technique. Observers assessed more noise in the low-dose images (P < 0.001). The normal structures were judged to be more visible with standard dose (P < 0.01), but the magnitude of the judged differences was small especially in the lung. No differences were found in the detection of lung and mediastinal abnormalities (P > 0.10).
CONCLUSIONS: The low-dose technique was effective in demonstrating pathologic findings for the lung and mediastinum. Low-dose spiral CT should be considered as a viable alternative to standard-dose spiral CT.

Entities:  

Mesh:

Year:  1998        PMID: 9493720     DOI: 10.1097/00004424-199802000-00002

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  14 in total

1.  Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

Authors:  Jens Ricke; Frank Fischbach; Torsten Freund; Ulf Teichgräber; Enrique Lopez Hänninen; Rainer Röttgen; Ulrike Engert; Hermann Eichstädt; Roland Felix
Journal:  Eur Radiol       Date:  2003-06-19       Impact factor: 5.315

Review 2.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

3.  Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality.

Authors:  Maninderpal Kaur Gill; Anushya Vijayananthan; Gnana Kumar; Kasthoori Jayarani; Kwan-Hoong Ng; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2015-08

Review 4.  Screening for lung cancer with low-dose computed tomography: a review of current status.

Authors:  Henry M Marshall; Rayleen V Bowman; Ian A Yang; Kwun M Fong; Christine D Berg
Journal:  J Thorac Dis       Date:  2013-10       Impact factor: 2.895

5.  Environmental asbestos disease: pleural plaque volume measurement with Chest Tomography is there a correlation between pulmonary function?

Authors:  Ibrahim Güven Çoşğun; Fatma Evyapan; Nevzat Karabulut
Journal:  Sarcoidosis Vasc Diffuse Lung Dis       Date:  2017-04-28       Impact factor: 0.670

6.  Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT.

Authors:  Sadi Gündoğdu; Kamran Mahmutyazicioğlu; Hüseyin Ozdemir; Ahmet Savranlar; Kiyasettin Asil
Journal:  Eur Radiol       Date:  2004-12-02       Impact factor: 5.315

7.  Dose management in CT facility.

Authors:  V Tsapaki; M Rehani
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

Review 8.  Radiation exposure from chest CT: issues and strategies.

Authors:  Mannudeep K Kalra; Michael M Maher; Stefania Rizzo; David Kanarek; Jo-Anne O Shepard; Jo-Anne O Shephard
Journal:  J Korean Med Sci       Date:  2004-04       Impact factor: 2.153

9.  Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT.

Authors:  Hye Jeon Hwang; Joon Beom Seo; Jin Seong Lee; Jae-Woo Song; Song Soo Kim; Hyun Joo Lee; Chae Hun Lim
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

10.  Minimization of Radiation Exposure due to Computed Tomography in Inflammatory Bowel Disease.

Authors:  Patrick D Mc Laughlin; Owen J O'Connor; Siobhán B O'Neill; Fergus Shanahan; Michael M Maher
Journal:  ISRN Gastroenterol       Date:  2012-04-10