Literature DB >> 9493548

Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty.

J A Simon1, A J Dayan, E Ergas, S A Stuchin, P E Di Cesare.   

Abstract

Recent research in total hip arthroplasty has focused on attempts to decrease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9493548     DOI: 10.1016/s0883-5403(98)90085-7

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Incidence of ceramic liner malseating in Trident acetabular shell.

Authors:  Anna N Miller; Edwin P Su; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2009-03-12       Impact factor: 4.176

2.  Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis.

Authors:  Adolph V Lombardi; Keith R Berend; Brian E Seng; Ian C Clarke; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

Review 3.  Hip replacement in the athlete: is there a role?

Authors:  M J Wilson; R N Villar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-12       Impact factor: 4.342

4.  Metal ion levels comparison: Metal-on-metal hip resurfacing vs total hip arthroplasty in patients requiring revision surgery.

Authors:  Syed S Ahmed; Rajesh Bawale; Sunil Jain; Srinivas Samsani
Journal:  J Orthop       Date:  2018-09-28

Review 5.  Bearing surfaces in hip replacement - Evolution and likely future.

Authors:  Narinder Kumar; Gen N C Arora; Barun Datta
Journal:  Med J Armed Forces India       Date:  2014-08-04

6.  Prosthetic femoral head erosion through an acetabular component treated with revision and implant preservation.

Authors:  Mark Daniel Kohn; Navin Fernando
Journal:  Arthroplast Today       Date:  2020-01-14

7.  Do Not Postpone Revision of Worn Conventional Liners in Ceramic-on-Polyethylene Total Hip Arthroplasty: A New Dramatic Failure.

Authors:  Thorsten Gehrke; Mustafa Citak; Hussein Abdelaziz
Journal:  Arthroplast Today       Date:  2021-07-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.