Determination of impedance changes at varying frequencies in relation to root canal file position and irrigant.

T F Pilot1, D L Pitts.   

Abstract

This study was conducted on 10 anterior and premolar teeth that were scheduled for endodontic treatment. After length of tooth determination, a series of test K-file handles were locked at lengths varying from 3 mm short to 0.5 mm long of the foramen. Samples of impedance were taken at each length with a digital signal processor at six different frequencies and for each of seven different irrigants or canal conditions. A total of five different root canal irrigants were used in each tooth (RC Prep, 70% isopropyl alcohol, 14.45% EDTA sodium solution, normal saline, and 5.25% NaOCl), along with two variations of a dry canal. The greatest impedance changes occurred +/- 0.25 mm from the foramen. No significant difference was noted in prediction error at different frequencies (p > 0.05); however, prediction error was significant with respect to different irrigants (p < 0.02). Conductive irrigants demonstrated less change of electrical characteristics with length than nonconductive irrigants, thus allowing a greater prediction of file position in relation to the foramen using electrically nonconductive irrigants.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9487844     DOI: 10.1016/S0099-2399(97)80341-X

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer-an in vitro study.

Authors:  Franziska Haupt; M Hülsmann
Journal:  Clin Oral Investig       Date:  2018-03-07       Impact factor: 3.573

2.  Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  J Paras Mull; Vinutha Manjunath; Mk Manjunath
Journal:  J Conserv Dent       Date:  2012-04

3.  Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

Authors:  Pil-Jong Kim; Hong-Gee Kim; Byeong-Hoon Cho
Journal:  Restor Dent Endod       Date:  2014-12-26

4.  A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.

Authors:  Irfana Khursheed; Ruchika Bansal; Tajinder Bansal; Harkanwal Preet Singh; Madhulika Yadav; K Jetender Reddy
Journal:  Dent Res J (Isfahan)       Date:  2014-01

5.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

6.  The Effect of File Size and Type and Irrigation Solutions on the Accuracy of Electronic Apex Locators: An In Vitro Study on Canine Teeth.

Authors:  Maciej Janeczek; Piotr Kosior; Dagmara Piesiak-Pańczyszyn; Krzysztof Dudek; Aleksander Chrószcz; Agnieszka Czajczyńska-Waszkiewicz; Małgorzata Kowalczyk-Zając; Aleksandra Gabren-Syller; Karol Kirstein; Aleksandra Skalec; Ewelina Bryła; Maciej Dobrzyński
Journal:  Biomed Res Int       Date:  2016-09-26       Impact factor: 3.411

7.  An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files.

Authors:  Paras Mull Gehlot; Vinutha Manjunath; Mysore Krishnaswamy Manjunath
Journal:  Restor Dent Endod       Date:  2016-01-04

8.  Influence of Open Apex on Working Length Determination Using Cone-Beam Computed Tomography and Apex Locators: A Comparative In Vitro Study.

Authors:  Swati Srivastava; Hanan M Alharbi; Mai Soliman; Elzahraa Eldwakhly; Manal M Abdelhafeez
Journal:  Biomed Res Int       Date:  2022-07-23       Impact factor: 3.246

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.