Literature DB >> 9484057

The effect of displacement time on gingival crevice width.

H Baharav1, B Z Laufer, Y Langer, H S Cardash.   

Abstract

The authors investigated the length of time medicated displacement cord should remain in the gingival crevice prior to impression making. A silk cord (Deknatel) was placed into the sulcus and was not removed during the study. Medicated cords (Hemodent on Ultrapak #1) were placed into the gingival sulcus for 2, 4, 6, and 8 minutes. Following cord removal, closure of the sulcus was recorded at intervals using a miniature video camera. Crevicular widths were measured at the midbuccal and transitional line angle areas. At both the midbuccal and transitional line angle areas, gingival crevices displaced for 2 minutes were significantly smaller at 20 seconds (P < .05) than crevices following displacement for 4, 6, and 8 minutes. No significant difference in crevicular width was found at any time period after cord removal for crevices displaced for 4, 6, and 8 minutes. At the transitional line angle, crevicular widths were significantly smaller than at the midbuccal at 20 seconds for all times and remained so up to 180 seconds. To achieve a crevicular width of 0.2 mm, cord should remain in the gingival crevice for an optimum time of 4 minutes prior to impression making when using the materials evaluated in this study.

Mesh:

Year:  1997        PMID: 9484057

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  5 in total

1.  Effect of the impression margin thickness on the linear accuracy of impression and stone dies: an in vitro study.

Authors:  Y G Naveen; Raghunath Patil
Journal:  J Indian Prosthodont Soc       Date:  2012-08-03

2.  The Influence of Hemostatic Agents and Cordless Gingival Retraction Materials on Smear Layer: An Ex vivo Scanning Electron Microscope Analysis.

Authors:  Shailendra Kuamar Sahu; Suhasini J Nagda
Journal:  Int J Appl Basic Med Res       Date:  2021-07-19

3.  Assessment of crown and bridge work quality among Sudanese dental practitioners.

Authors:  A B Mohamed; Neamat Hassan Abu-Bakr
Journal:  J Indian Prosthodont Soc       Date:  2010-08-05

4.  Comparative evaluation of three gingival displacement materials for efficacy in tissue management and dimensional accuracy.

Authors:  Vijeta Gajbhiye; Rajlakshmi Banerjee; Priti Jaiswal; Anuj Chandak; Usha Radke
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

5.  Comparative Evaluation of the Clinical Efficacy of Four Different Gingival Retraction Systems: An In Vivo Study.

Authors:  Rahul Madaan; Jyoti Paliwal; Vineet Sharma; Kamal K Meena; Ashish Dadarwal; Roshni Kumar
Journal:  Cureus       Date:  2022-04-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.