Literature DB >> 9483932

[3-dimensional photogrammetry assessment of facial contours].

D Kakoschke1, H Gäbel, D Schettler.   

Abstract

In Germany, three-dimensional non-invasive measurement techniques are not in routine use for medical purposes. Completely integrated applications of photogrammetric technology are lacking. The results of clinical examination, X-rays and pre- and postoperative photographs from different angles have been used for medical analysis. In an interdisciplinary research project we tested the general applicability of photogrammetric measurement systems. We examined patients with malformations of the mandible-maxilla complex by taking pictures of the face. In order to assess the surface structure we projected regular patterns onto the surface. We calculated about 500 points on the surface with accuracy better than 0.2 mm. Graphical analyses of measurement results are presented in clinically relevant form. We produce representations of the faces in auto-CAD by means of regular meshes which allow views from any perspective, longitudinal and lateral sections. In addition to calculating angles, distances, surfaces and volumes, visualisation of shape is a useful aid in documentation and quantification of changes of soft tissue of the human face under surgery treatment.

Entities:  

Mesh:

Year:  1997        PMID: 9483932     DOI: 10.1007/BF03043511

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  7 in total

1.  [Metric and x-ray comparison of the middle face following periorbital fractures].

Authors:  H D Pape; M Galanski; F Rothe
Journal:  Fortschr Kiefer Gesichtschir       Date:  1977

2.  Three dimensional analysis of the face in respect of zygomatic fractures and evaluation of the surgery with the aid of Moiré topography.

Authors:  Y Kawano
Journal:  J Craniomaxillofac Surg       Date:  1987-04       Impact factor: 2.078

3.  Evaluation of the laser scanner as a surface measuring tool and its accuracy compared with direct facial anthropometric measurements.

Authors:  S C Aung; R C Ngim; S T Lee
Journal:  Br J Plast Surg       Date:  1995-12

4.  A three-dimensional soft tissue analysis of fifteen patients with Class II, Division 1 malocclusions after bimaxillary surgery.

Authors:  J P Moss; A M McCance; W R Fright; A D Linney; D R James
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-05       Impact factor: 2.650

5.  Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique.

Authors:  T Jemt; A Lie
Journal:  Clin Oral Implants Res       Date:  1995-09       Impact factor: 5.977

6.  Facial three-dimensional morphometry.

Authors:  V F Ferrario; C Sforza; C E Poggio; G Serrao
Journal:  Am J Orthod Dentofacial Orthop       Date:  1996-01       Impact factor: 2.650

7.  A three-dimensional soft tissue analysis of 16 skeletal class III patients following bimaxillary surgery.

Authors:  A M McCance; J P Moss; W R Wright; A D Linney; D R James
Journal:  Br J Oral Maxillofac Surg       Date:  1992-08       Impact factor: 1.651

  7 in total
  3 in total

1.  [Rapid prototyping in planning reconstructive surgery of the head and neck. Review and evaluation of indications in clinical use].

Authors:  J S Bill; J F Reuther
Journal:  Mund Kiefer Gesichtschir       Date:  2004-03-16

2.  [Virtual simulation of dental surgery using a three-dimensional computer model with a force feedback system].

Authors:  M Heiland; N Von Sternberg-Gospos; B Pflesser; D Schulze; K H Höhne; R Schmelzle; A Petersik
Journal:  Mund Kiefer Gesichtschir       Date:  2004-02-26

3.  Three-dimensional analysis of changes of the malar-midfacial region after LeFort I osteotomy and maxillary advancement.

Authors:  Emeka Nkenke; Eleftherios Vairaktaris; Manuel Kramer; Andreas Schlegel; Alexandra Holst; Ursula Hirschfelder; Jörg Wiltfang; Friedrich Wilhelm Neukam; Marc Stamminger
Journal:  Oral Maxillofac Surg       Date:  2008-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.