Literature DB >> 947687

Echocardiographic and phonocardiographic confirmation of suspected caged mitral valve malfunction.

T B Berndt, D J Goodman, R L Popp.   

Abstract

Seven patients studied by echocardiography with and without simultaneous phonocardiography for suspected malfunction of a caged mitral valve prosthesis are presented. In case 1, with inaudible prosthetic clicks, thrombosis of the cage and immobility of the ball were suggested by echocardiographic studies and confirmed at surgery. In case 2, simultaneous echocardiographic and phonocardiographic studies demonstrated wide and variable intervals between the aortic second sound the the opening click and also "sticking" of the ball. In case 3 a thrombus prevented full motion of the ball to the apex of the cage, which was seen on the echocardiogram, while in case 4, with a thrombus within the ventricle and prosthesis, the prosthetic opening click was present intermittently and was associated with only subtle echocardiographic changes. In case 5, echocardiographic studies demonstrated abnormal rocking of the cage secondary to severe prosthetic dehiscence. In case 6, dul prosthetic clicks were to be secondary to a low cardiac-output state. In case 7, with multiple valve prostheses, simultaneous echocardiographic and phonocardiographic studies allowed identification of individual valve sounds and abnormal timing of valve opening. Based on these studies, we believe that echocardiography and simultaneous phonocardiography can yield very useful information in the evaluation of patients with suspected malfunction of a caged mitral valve prosthesis.

Entities:  

Mesh:

Year:  1976        PMID: 947687     DOI: 10.1378/chest.70.2.221

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  6 in total

1.  ECHO-PHONOCARDIOGRAPHIC CHARACTERISTICS OF THE NORMALLY FUNCTIONING COOLEY-CUTTER MITRAL VALVE PROSTHESIS.

Authors:  Leonard W. Pechacek; Ali Zarrabi; Ali Massumkhani; Efrain Garcia; Carlos M. De Castro; Robert J. Hall
Journal:  Cardiovasc Dis       Date:  1979-12

2.  ACOUSTIC CHANGES IN NORMALLY FUNCTIONING MITRAL VALVE PROSTHESES: ECHO-PHONOCARDIOGRAPHIC OBSERVATIONS.

Authors:  Ulrich Busch; Leonard W. Pechacek; Efrain Garcia; Robert J. Hall
Journal:  Cardiovasc Dis       Date:  1978-06

3.  Noninvasive assessment of the Ionescu-Shiley pericardial xenograft in the mitral position: preliminary experience.

Authors:  L W Pechacek; L G Solana; C M DeCastro; S K Edelman; E Garcia; R J Hall
Journal:  Tex Heart Inst J       Date:  1982-09

Review 4.  Bioengineering aspects of heart valve replacement.

Authors:  F J Schoen; J L Titus; G M Lawrie
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

5.  Fibrinolytic treatment of thrombus on prosthetic heart valves.

Authors:  S Witchitz; C Veyrat; P Moisson; N Scheinman; L Rozenstajn
Journal:  Br Heart J       Date:  1980-11

Review 6.  Echocardiography in mitral valve disease: a review.

Authors:  J H Graf; R Meltzer
Journal:  Int J Card Imaging       Date:  1985
  6 in total