Literature DB >> 15226927

Noninvasive assessment of the Ionescu-Shiley pericardial xenograft in the mitral position: preliminary experience.

L W Pechacek1, L G Solana, C M DeCastro, S K Edelman, E Garcia, R J Hall.   

Abstract

To establish noninvasive criteria for assessment of the Ionescu-Shiley pericardial xenograft in the mitral position, 29 patients with a normally functioning bioprosthesis were studied with m-mode echocardiography and phonocardiography. Two-dimensional echocardiograms were also obtained in ten of the patients. Although two-dimensional echocardiography provided simultaneous visualization of a greater number of stents and leaflets than the m-mode technique, the superior resolution of m-mode ultrasound permitted more detailed analyses of the xenograft's motion patterns. The anterior leaflet, recorded in all patients, had an average excursion of 1.2 +/- 0.22 cm. Leaflet thickness measured 4 mm or less. Coarse diastolic vibration of the anterior leaflet was recorded in two patients in the absence of both aortic insufficiency and prosthesis dysfunction. Ultrasonic estimates of prosthesis height and orifice diameter did not correlate with micrometer measurements, possibly due to the limited resolution of pulsed ultrasound in the presence of a highly reflective substance. Opening and closing of the pericardial leaflets were associated with the production of high frequency vibrations on the phonocardiogram. The potential usefulness and limitations of echocardiography for evaluating the function of bioprosthetic valves are discussed.

Entities:  

Year:  1982        PMID: 15226927      PMCID: PMC351627     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  26 in total

1.  Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.

Authors:  Leonard W. Pechacek; Luis Solana; Carlos M. Decastro
Journal:  Cardiovasc Dis       Date:  1981-06

2.  Echocardiographic evaluation of the stent mounted aortic bioprosthetic valve in the mitral position. In vitro and in vivo studies.

Authors:  M S Horowitz; P L Tecklenberg; D J Goodman; D C Harrison; R L Popp
Journal:  Circulation       Date:  1976-07       Impact factor: 29.690

3.  Echocardiographic studies of stented fascia lata grafts in the mitral position.

Authors:  D A Mary; B C Pakrashi; R W Catchpole; M I Ionescu
Journal:  Circulation       Date:  1974-02       Impact factor: 29.690

4.  Echocardiographic features of the normal and malfunctioning porcine xenograft valve.

Authors:  P A Chandraratna; S B San Pedro
Journal:  Am Heart J       Date:  1978-05       Impact factor: 4.749

5.  Echocardiographic evaluation of porcine heterograft valves in the mitral and aortic positions.

Authors:  W E Harston; R M Robertson; G C Friesinger
Journal:  Am Heart J       Date:  1978-10       Impact factor: 4.749

6.  Long-term clinical and hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve.

Authors:  M I Ionescu; A P Tandon
Journal:  Artif Organs       Date:  1980-02       Impact factor: 3.094

7.  Clinical utility of two-dimensional echocardiography in patients with bioprosthetic valves.

Authors:  R P Martin; J W French; R L Popp
Journal:  Adv Cardiol       Date:  1980

8.  Echo-phonocardiographic evaluation of obstruction of prosthetic mitral valve.

Authors:  A D Waggoner; M A Quiñones; J B Young; J G Nelson; W L Winters; P K Peterson; R R Miller
Journal:  Chest       Date:  1980-07       Impact factor: 9.410

9.  Echocardiogram of the porcine aortic bioprosthesis in the mitral position.

Authors:  W N Bloch; J M Felner; C Wickliffe; P N Symbas; R C Schlant
Journal:  Am J Cardiol       Date:  1976-09       Impact factor: 2.778

10.  Heart valve replacement with the Ionescu-Shiley pericardial xenograft.

Authors:  M I Ionescu; A P Tandon; D A Mary; A Abid
Journal:  J Thorac Cardiovasc Surg       Date:  1977-01       Impact factor: 5.209

View more
  1 in total

1.  Two-dimensional echocardiographic features of sewing ring dehiscence of a bioprosthetic mitral valve.

Authors:  L W Pechacek; N E Strickman; L G Solana; R Leon
Journal:  Tex Heart Inst J       Date:  1983-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.