Literature DB >> 9458978

Comparison of BACTEC plus Aerobic/F, Anaerobic/F, Peds Plus/F, and Lytic/F media with and without fastidious organism supplement to conventional methods for culture of sterile body fluids.

D D Fuller1, T E Davis.   

Abstract

We compared the BACTEC 9240 continuous-read instrument using Peds Plus/F, Lytic/F, Aerobic/F, and Anaerobic/F media (Becton Dickinson Diagnostic Instrument Systems, Sparks, MD) with and without fastidious organism supplement to conventional centrifugation preparation and plating for the recovery and speed of detection of microorganisms. A total of 908 sterile body fluid specimens were collected and processed, yielding 116 (13%) positive cultures. Of the 80 isolates considered clinically significant, 48 (60%) were recovered by both the BACTEC system and conventional culture, whereas 32 (40%) were recovered by BACTEC only. No clinically significant isolates were recovered only by conventional culture methods. The time to detection for isolates recovered from both sets was faster for BACTEC. It was found that BACTEC, with or without the addition of fastidious organisms supplement, exhibited improved sensitivity for the recovery of microorganisms.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9458978     DOI: 10.1016/s0732-8893(97)00164-8

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  9 in total

1.  False-negative culture results with fungal isolates from peritoneal dialysis fluid.

Authors:  Jason D Pimentel; Gary D Lum
Journal:  J Clin Microbiol       Date:  2006-03       Impact factor: 5.948

2.  The BD BACTEC FX blood culture system with the gentlemacs dissociator is suitable for sterility testing of heart valve and vascular allografts-A validation study.

Authors:  Ramadan Jashari; Sarah Vanzeebroeck; Pieter Petit; Hector Rodriguez-Villalobos; Sharon Zahra; Naziha Ben Said; Vanessa Bouzet; Stefano Mastrobuoni
Journal:  Cell Tissue Bank       Date:  2021-01-08       Impact factor: 1.522

3.  Comparison of BacT/Alert FAN and FAN Plus Bottles with Conventional Medium for Culturing Cerebrospinal Fluid.

Authors:  In Young Yoo; Sejong Chun; Dong Joon Song; Hee Jae Huh; Nam Yong Lee
Journal:  J Clin Microbiol       Date:  2016-09-14       Impact factor: 5.948

4.  Evaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood.

Authors:  D D Fuller; T E Davis; G A Denys; M K York
Journal:  J Clin Microbiol       Date:  2001-08       Impact factor: 5.948

5.  Use of a pair of blood culture bottles for sterility testing of corneal organ culture media.

Authors:  P Gain; G Thuret; C Chiquet; A C Vautrin; A Carricajo; S Acquart; J Maugery; G Aubert
Journal:  Br J Ophthalmol       Date:  2001-10       Impact factor: 4.638

6.  PCR and blood culture for detection of Escherichia coli bacteremia in rats.

Authors:  A Heininger; M Binder; S Schmidt; K Unertl; K Botzenhart; G Döring
Journal:  J Clin Microbiol       Date:  1999-08       Impact factor: 5.948

7.  Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.

Authors:  G Thuret; A Carricajo; C Chiquet; A C Vautrin; N Celle; M Boureille; S Acquart; G Aubert; J Maugery; P Gain
Journal:  Br J Ophthalmol       Date:  2002-12       Impact factor: 4.638

8.  Rapid identification of bacteria and Candida using PNA-FISH from blood and peritoneal fluid cultures: a retrospective clinical study.

Authors:  Dana M Harris; D Jane Hata
Journal:  Ann Clin Microbiol Antimicrob       Date:  2013-01-07       Impact factor: 3.944

9.  Evaluation of flow cytometry for the detection of bacteria in biological fluids.

Authors:  Elisa Rubio; Yuliya Zboromyrska; Jordi Bosch; Mariana J Fernandez-Pittol; Berta I Fidalgo; Assumpta Fasanella; Anna Mons; Angely Román; Climent Casals-Pascual; Jordi Vila
Journal:  PLoS One       Date:  2019-08-07       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.