Literature DB >> 11474016

Evaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood.

D D Fuller1, T E Davis, G A Denys, M K York.   

Abstract

MYCO/F Lytic medium (MFL), a liquid medium developed for use with the BACTEC 9240 blood culture system, was compared to the Isolator system (IS) for the recovery of fungi and to the BACTEC 13A medium for the recovery of mycobacteria. Recovery of bacteria was compared to routine BACTEC Plus Aerobic/F (AF) blood cultures. Microbial growth was detected in 203 (17%) of 1,166 blood cultures. Fifty-seven specimens were positive for fungi: 35 were positive with both IS and MFL; six were positive with IS only (three Candida albicans, one Histoplasma capsulatum, one Candida glabrata, and one Fusarium species isolate); three were positive with AF only (two C. albicans and one Candida parapsilosis isolate); and 13 were positive with MFL only (five C. glabrata, three C. albicans, two Candida krusei, two Candida tropicalis, and one C. parapsilosis isolate; P > 0.05 versus IS). Eighteen of 19 blood cultures positive for H. capsulatum grew in both IS and MFL, although the time to detection for MFL was greater. The mean time to detection for all fungi was 8.15 days for IS and 12.07 days for MFL. Seven hundred forty specimens were also cultured for mycobacteria with MFL and 13A. Forty-four grew mycobacteria; 38 were positive with both 13A and MFL; and 16 were positive with MFL only. Mycobacterium avium was recovered from 41 specimens; 36 were positive for both systems and 5 were positive for MFL alone. MFL was also compared to the AF bottle for the same 740 specimens. MFL and AF both detected 34 of the 40 clinically significant bacteria, while IS detected only 15 of 40. In summary, MFL is an excellent medium for the recovery of fungi, mycobacteria, and bacteria; however, the time to detection of H. capsulatum is increased.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11474016      PMCID: PMC88263          DOI: 10.1128/JCM.39.8.2933-2936.2001

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

Review 2.  Statistical methods in microbiology.

Authors:  D M Ilstrup
Journal:  Clin Microbiol Rev       Date:  1990-07       Impact factor: 26.132

3.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

4.  Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).

Authors:  F S Nolte; J M Williams; R C Jerris; J A Morello; C D Leitch; S Matushek; L D Schwabe; F Dorigan; F E Kocka
Journal:  J Clin Microbiol       Date:  1993-03       Impact factor: 5.948

5.  Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children.

Authors:  C A Petti; A K Zaidi; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

6.  The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations.

Authors:  M P Weinstein; L B Reller; J R Murphy; K A Lichtenstein
Journal:  Rev Infect Dis       Date:  1983 Jan-Feb

7.  Clinical impact of bacteria and fungi recovered only from broth cultures.

Authors:  A J Morris; S J Wilson; C E Marx; M L Wilson; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1995-01       Impact factor: 5.948

8.  Histoplasmosis relapse in patients with AIDS: detection using Histoplasma capsulatum variety capsulatum antigen levels.

Authors:  L J Wheat; P Connolly-Stringfield; R Blair; K Connolly; T Garringer; B P Katz
Journal:  Ann Intern Med       Date:  1991-12-15       Impact factor: 25.391

9.  Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.

Authors:  M L Wilson; T E Davis; S Mirrett; J Reynolds; D Fuller; S D Allen; K K Flint; F Koontz; L B Reller
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

10.  Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

Authors:  J K Pohlman; B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1995-11       Impact factor: 5.948

View more
  9 in total

1.  Use of the BACTEC MYCO/F LYTIC medium for detection of Brucella melitensis bacteremia.

Authors:  Pablo Yagupsky
Journal:  J Clin Microbiol       Date:  2004-05       Impact factor: 5.948

2.  Evaluation of a Rapid Fungal Detection Panel for Identification of Candidemia at an Academic Medical Center.

Authors:  John P Bomkamp; Rand Sulaiman; Jennifer L Hartwell; Armisha Desai; Vera C Winn; Justin Wrin; Michelle L Kussin; Jon J Hiles
Journal:  J Clin Microbiol       Date:  2020-02-24       Impact factor: 5.948

3.  Visible DNA Microarray System as an Adjunctive Molecular Test in Identification of Pathogenic Fungi Directly from a Blood Culture Bottle.

Authors:  Lais Lovison Sturaro; Tohru Gonoi; Ariane Fidelis Busso-Lopes; Cibele Aparecida Tararam; Carlos Emilio Levy; Luzia Lyra; Plinio Trabasso; Angélica Zaninelli Schreiber; Katsuhiko Kamei; Maria Luiza Moretti
Journal:  J Clin Microbiol       Date:  2018-04-25       Impact factor: 5.948

4.  Comparison of the BACTEC MYCO/F Lytic bottle to the isolator tube, BACTEC Plus Aerobic F/bottle, and BACTEC Anaerobic Lytic/10 bottle and comparison of the BACTEC Plus Aerobic F/bottle to the Isolator tube for recovery of bacteria, mycobacteria, and fungi from blood.

Authors:  E Vetter; C Torgerson; A Feuker; J Hughes; S Harmsen; C Schleck; C Horstmeier; G Roberts; F Cockerill
Journal:  J Clin Microbiol       Date:  2001-12       Impact factor: 5.948

5.  Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.

Authors:  John A Crump; David C Tanner; Stanley Mirrett; Celeste M McKnight; L Barth Reller
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

6.  Insidious Risk of Severe Mycobacterium chimaera Infection in Cardiac Surgery Patients.

Authors:  Meera Chand; Theresa Lamagni; Katharina Kranzer; Jessica Hedge; Ginny Moore; Simon Parks; Samuel Collins; Carlos Del Ojo Elias; Nada Ahmed; Tim Brown; E Grace Smith; Peter Hoffman; Peter Kirwan; Brendan Mason; Alison Smith-Palmer; Philip Veal; Maeve K Lalor; Allan Bennett; James Walker; Alicia Yeap; Antonio Isidro Carrion Martin; Gayle Dolan; Sonia Bhatt; Andrew Skingsley; André Charlett; David Pearce; Katherine Russell; Simon Kendall; Andrew A Klein; Stephen Robins; Silke Schelenz; William Newsholme; Stephanie Thomas; Tim Collyns; Eleri Davies; Jim McMenamin; Lorraine Doherty; Tim E A Peto; Derrick Crook; Maria Zambon; Nick Phin
Journal:  Clin Infect Dis       Date:  2016-12-07       Impact factor: 20.999

7.  A dedicated fungal culture medium is useful in the diagnosis of fungemia: a retrospective cross-sectional study.

Authors:  Shuwei Zheng; Tong Yong Ng; Huihua Li; Ai Ling Tan; Thuan Tong Tan; Ban Hock Tan
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

8.  Evaluation of the efficacy of Myco/F lytic system, MGIT960 system and Lowenstein-Jensen medium for recovery of Mycobacterium tuberculosis from sterile body fluids.

Authors:  Guirong Wang; Xinting Yang; Junping Zhu; Weijie Dong; Mailing Huang; Guanglu Jiang; Liping Zhao; Sibing Qin; Xiaoyou Chen; Hairong Huang
Journal:  Sci Rep       Date:  2016-11-23       Impact factor: 4.379

Review 9.  Diagnosis of active tuberculosis disease: From microscopy to molecular techniques.

Authors:  Adam J Caulfield; Nancy L Wengenack
Journal:  J Clin Tuberc Other Mycobact Dis       Date:  2016-05-25
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.